Energy Guide

Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction
allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied.
U.L. recognized under le number MH 20567.
L: 7.75 in (197 mm)
W: 5.19 in (132 mm)
H: 6.26 in (159 mm)
TH: 6.26 in (159 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
Nominal Voltage
Nominal Capacity
20-hr. (1.75A)
10-hr. (3.26A)
5-hr. (5.96A)
1-hr. (21.0A)
Approximate Weight
Internal Resistance (approx.)
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months 6 Months 12 Months
12 volts
35.0 Ah
10.5 A or smaller
14.6 - 14.8 V
77º F (25º C)
32.6 Ah
29.8 Ah
21.0 Ah
23.2 lbs (10.5 kgs)
10m
91% 83% 64%
Charge Method (Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
13.6 - 13.8 V
Control Voltage
(Repeating Use)
Specification
Physical Dimensions: in (mm)
Terminals
Sealed Lead-Acid Battery
UPG No. 45976
UB12350
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HRF.V/Time
122.0 89.0 63.0 38.0 19.8 12.0 8.5 6.6 5.4 3.8 3.5 1.99.60V
108.0 81.0 56.0 36.0 18.6 11.0 8.3 6.4 5.3 3.8 3.4 1.810.20V
104.0 77.0 53.0 35.0 18.0 10.8 8.1 6.3 5.3 3.7 3.3 1.810.50V
100.0 73.0 50.0 34.0 17.0 10.5 7.9 6.2 5.1 3.6 3.3 1.810.80V
96.0 69.0 46.0 33.0 17.0 10.2 7.6 6.0 5.0 3.5 3.1 1.711.10V
Constant Current Discharge Characteristics Unit:A (25°C, 77°F)
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HRF.V/Time
1297.0 946.0 666.0 403.0 229.0 134.0 98.0 76.0 63.0 44.0 40.0 21.79.60V
1194.0 901.0 623.0 399.0 216.0 128.0 96.0 75.0 62.0 43.0 39.0 21.110.20V
1175.0 876.0 599.0 397.0 209.0 125.0 93.0 73.0 61.0 43.0 39.0 20.910.50V
1160.0 853.0 576.0 396.0 203.0 122.0 91.0 72.0 60.0 42.0 38.0 20.710.80V
1139.0 825.0 550.0 393.0 200.0 122.0 90.0 71.0 60.0 42.0 37.0 20.111.10V
Constant Power Discharge Characteristics Unit:W (25°C, 77°F)
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
All specifications subject to change without notice.
L1713-1
Temperature Dependancy of Capacity
104 F (40 C) 77 F (25 C)
(20 hour rate)
102% 100% 85%
32 F (0 C) 5 F (-15 C)
65%
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
7.75 (197)
6.26 (159)
5.19 (132)
Copyright 2017 Universal Power Group Inc. All rights reserved.
Due to continuous improvements to our products, product may vary slightly from depiction.
Maintenance-Free

Summary of content (2 pages)