Quick Start Guide
Check the connectivity of the AC Pins and also at the AC Cable to make sure that
Line or Neutral pins are NOT connected to the ground
Connect the low power KU Band output from a low power BUC or indoor upconverter to
the labeled port. Nominal input levels are approximately +20 dBm depending on the
output power level of the unit.
Connect the rigid waveguides to the SSPA’s RF outputs and to the waveguide switch as
indicated in the Redundancy Diagram
Connect to the “Y” Cable supplied with the units to the “Switch “ Ports at the units and to
the control port of the waveguide switch.
The SSPA’s output is taken from the waveguide port (RF Out). Caution should be
observed here to make sure that the antenna or a suitable termination is connected to
this port before operating the SSPA.
Ensure there is proper clearance around the unit.
Connect the chassis ground (GND) to a proper ground connection
Connect AC Input power to the connector. The unit will be enabled almost immediately,
provided it is not forced into a mute state.
Connect the M & C interface to an available COM port on your computer and/or to your
analog based monitoring and control equipment.
Run the UPCOM TECHNOLOGIES Monitor and Control Program.
Recommendation: if possible install the SSPA with the fans facing down in order
to avoid accumulation of debris inside the fans that may block the fans.