Descaling
When the flow is reduced, the water purifier should be
descaled to extend its lifetime. When the flow cannot be
restored despite descaling and filter replacement, contact
your dealer. During the descaling procedure, which takes
around 10 hours, the water purifier cannot be used.
The descaling product can be ordered from your dealer,
see «Consumables».
The descaling product must be kept out
of the reach of children! Wash your hands
after using it.
1. Check that the water purifier is in standby
mode.
2. Press the service button, using a pen, until
the service light comes on. Release the button.
The light on the faucet now flashes rapidly for
15 seconds. This will prevent flushing from
taking place during descaling.
3. Unscrew the filter container in accordance
with «Replacing the filter», points 2 - 5.
Remove the filter and put it a side.
4. Mix 50 g (approx. 1/4 of the bag) of the desca-
ling product with 7 dl of lukewarm water.
Stir until the powder has dissolved, see fig. A.
5. Screw the filled container in place.
6. Start the water purifier and produce pure
water for 30 seconds.
7. While production is still in progress, pull
out the plug, see fig. B.
8. Allow the water purifier to stand for approx.
10 hours (e.g. overnight).
9. Undo the container and empty the water.
Replace the filter in accordance with
«Replacing the filter», points 7 - 8, except
that the previously used filter is used here.
10. Close the front cover and connect the plug.
11. Flush the water purifier in accordance with
«Flushing».
Do not use the purified water until
flushing is complete.
The descaling process is now finished. The water
purifier is ready to be used.