User`s guide

4.2.4 Geographical ID Setting
ID switch is used to decide identification, CPU number and type of server.
ServerDome is monitoring on the basis of identification, CPU number and type of server.
1
ON
234 1
ON
2345678
ID
0
10
124
Binary
00000000
00001010
01111100
1
OFF
OFF
OFF
2
OFF
ON
OFF
3
OFF
OFF
ON
4
OFF
ON
ON
5
OFF
OFF
ON
6
OFF
OFF
ON
7
OFF
OFF
ON
8
OFF
OFF
OFF
Switches(B)
ID Assignment
This sets up identification information of server.
CPU Number
1
2
Binary
00
01
Description
1-way
2-way
1
OFF
ON
2
OFF
OFF
3
4
10
11
3-way
4-way
OFF
ON
ON
ON
Switches(A)
CPU Assignment
This sets up CPU number of server.
Type
1U
3U
3U
Binary
00
01
10
Description
2way Passive
2way Active/4way
Only 2way Passive
3
OFF
ON
OFF
4
OFF
OFF
ON
Switches(A)
Server Type Assignment
This sets up server type.
A B
CAUTION
You have to install the ID switch before BMC F/W update.
61