For best long-term performance, operators should follow these simple practices:
Lightly lubricate the beater shaft (Fig.1 [111) after washing. Petro-Gel or equivalent food
grade lubricant should be used.
Do not cover the unit with a plastic bag, as this traps humidity in your mixer.
If the electrical supply cord is damaged, it must be replaced by a special cord or assembly
available from Univex directly or from a Univex service agent.
Do not overload the mixer. Overloading is the # i cause of mixer failure. Follow the
Table ofMixing Capacities on page 14. It may be helpful to post a copy of this table adjacent
to the mixer.
Keep the mixer properly lubricated. Lack of lubrication is the #2 cause of mixer failure.
Key mixer components require lubrication after each 500 hours of operation. (Instructions
on frequency and method of lubricating appear in the enclosed Mechanic's Maintenance
booklet.)
Only change speed with the mixer running. Changing speed with the mixer off will cause
belts to loosen, and the mixer will not turn (see Trouble-Shooting Guide on page 12).
Return to speed i before shutting the mixer off, Use the procedure described on page 8 to
return the mixer to speed i if mixer is shut off in a higher speed.