Specifications
Electrical connections should be made my
qualified workmen who will observe all
applicable safety codes and the National
Electrical Code.
Before making electrical connections, check
the specifications on the data plate (located on
the rear access panel) to assure they agree with
those ofyour electrical service.
WARNING: DISCONNECT ELECTRICAL
POWER SUPPLY AT THE MAIN
CIRCUIT BOX AND PLACE A TAG
INDICATING THE CIRCUIT IS BEING
WORKED ON.
A hole of 112" conduit is located in the left
surface of the housing in the rear uppermost
location. Connect the input power leads to the
pigtail leads for the motor controller. A solder
less lug is provided for the service ground lead.
Secure service ground to the grounding stud
located to the left ofthe conduit hole.
Three-phase machines must be connected so the
beater head (planetary) turns in the direction of
the arrow (left to right). To check the direction
of rotation, turn the power disconnect switch
'ON". Place timer on 'HOLD". Energize
machine momentarily by pushing "START'
then "STOP" and verify the direction of
rotation.
WARNING: DISCONNECT
ELECTRICAL POWER SUPPLY AT THE
FUSED DISCONNECT SWITCH AND
PLACE A TAG INDICATING THE
CIRCUIT IS BEING WORKED ON.
If motor rotation is incorrect, interchange any
two ofthe power supply leads.
NOTE: It is not necessary to remove the top
cover ofthe mixer in order to perform the
electrical installation. Only the rear access
panel (FiglO [22]) need be removed,
ELECTRICAL CONNECTIONS
Page 39
SINGLE PHASE
GROUND
STUD
THREE PHASE
LUG
GROUND
STUD
LUG
MIXER ROTATION
SRM6O+/SRMSO+
PIGTML
LEADS
PIGTAIL
LEADS
BEATER HEAD
DIRECTION