- Nikon Autofocus Speedlight User's Manual

F2
F
Tips on Speedlight care and reference information
Troubleshooting
If a warning indicator appears, use the following chart to determine the cause of the
problem before you take your Speedlight to a retailer or Nikon representative for repair.
Problems with the SB-900
Problem Cause Solution
Ref.
page
The power cannot be
turned on.
The batteries are not
correctly installed.
Insert the batteries correctly.
k
C-4
Battery power is weak. Replace the batteries.
k
C-27
The ready-light does not
light up.
The standby function is activated.
Turn on the power.
k
C-28
Battery power is weak. Replace the batteries.
k
C-27
A strange sound can
be heard caused by the
ash head zooming back
and forth even when the
SB-900 is turned on.
Battery power is weak. Replace the batteries.
k
C-27
The fl ash shooting
distance range does not
appear.
The fl ash head is not set to the
horizontal/front position.
Set the fl ash head to the
horizontal/front position.
k
C-6
Aperture information has not
been received from the camera.
Confirm the camera setting.
Mount the SB-900 to a
camera.
•—
ISO sensitivity information has not
been received from the camera.
The SB-900 cannot receive the
focal length information from
the camera.
Turn off the SB-900 and camera,
and turn on them again.
Zoom position does not
set automatically.
The built-in wide-fl ash adapter
is in use or the Nikon Diffusion
Dome is attached.
Remove the wide-
flash adapter or the
Diffusion Dome.
Set the following custom
setting to manual setting:
“Zoom position setting if the
built-in wide-flash adapter is
broken off accidentally.”
k
D-29
k
D-31
k
C-25
Power zoom function
is canceled.
Activate the auto power
zoom function.
k
D-57
The SB-900 does not
work even when any
button is pressed.
Control buttons are locked
.
Cancel key lock.
k
C-9
The SB-900 does not
re.
“Canceling fl ash fi ring”
is activated in the custom
setting.
Cancel “Canceling fl ash fi ring”
in custom setting.
k
C-23
Master and remote fl ash units
cannot transmit the command
because they are positioned
too near.
Place the master and remote
ash units at an appropriate
distance from each other.
k
D-44
k
D-51
The SB-900’s temperature
may rise
Wait until the SB-900 cools
down naturally.
k
F-6