Manual

ROTORBAKE Series Ovens - electric version - Page 32
OPERATION AND FUNCTIONS OF THE 10 PROGRAMS EXTRA OVEN
THE OVEN:
The BAKE OFF 10 PROGRAMS EXTRA MODEL oven is designed to simplify the baking
of different items such as breads of all kinds, confectionery, pizza, etc.
Using computerized technology, it is able to memorize 10 programs for baking the same
number of different products, optimising all the parameters, which may vary while baking is
in progress.
Once all the programs to be used have been set, the operator has only to recall the number
of the program required and start baking.
Using an internal clock, the oven is also able to start baking at a preset time, so that the
operator can find the oven ready at the required temperature when he arrives at work.
INFORMATION ABOUT PROGRAMS
Before setting the definitive baking programs, users are advised to read the whole section
relating to use of the oven.
In each program, all the parameters essential for baking must be set: baking time, baking
temperature and steam injection time.
HOW TO SET PROGRAMS
Make sure that all oven connection procedures have been carried out correctly, then term
the main switch G, and turn on the oven’s computerized control by pressing the on - off
key:
First select the baking program to be set by pressing the program key N ; the relative
number will start to flash on the program display L, modify this number using the (+) key O,
and the (-) key M, then confirm the setting by pressing the Enter key P.
Then memorize the baking temperature of this program by pressing the Temperature key
R; the relative display F, will start to flash, modify the baking temperature using the (+) key
O, and the (-) key M, then confirm the setting by pressing the Enter key P.
The next step is to memorize the baking time, indicated in minutes, by pressing the Time
key T, the relative display H, will start to flash, modify the baking time using the (+) key O,
and the (-) key M, then confirm the setting by pressing the Enter key P.
To conclude, memorize the steam injection time, indicated in sencods, by pressing the
Steam key Q, followed by the (+) key O, and the (-) key M, then confirm the setting by
pressing the Enter key P.