Instruction manual

8512
ELECTRICAL ASSEMBLY
1.
WARNING DISCONNECT ELECTRICAL SUPPLY
2.
Remove four rubber feet (Fig. 2 [24]) and 4 extension legs (Fig. 2 [52]).
3.
Remove bottom cover (Fig. 2 [19]).
4.
Remove casing cover (fig. 8 [22]).
5.
Discharge capacitors by jumping across terminals with electrically protected screwdriver.
6.
Remove reduction gear rod (Fig. 2 [34]) by removing two bolts (Fig. 2 [38]) and removing
set screw at reduction gear end.
7.
Remove switch shaft (Fig. 8 [16]) by loosening nut (Fig. 8 [15]) near switch end.
8.
Remove capacitor on left to access ground screw holding electrical equipment casing.
9.
Remove electrical equipment casing by removing three screws (Fig. 8 [21 ]).
10.
Replace capacitors (Fig. 8 [24]) if found to be defective.
11.
Relay (Fig. 8 [7]) and switch (Fig. 8 [20]) can also be checked from this procedure.
12.
Replace any defective electrical component and reverse procedures to reassemble.
Page 11