Manual

B6TTR-B10TTR page. 83
Research very useful mode to filter the desired recipe when there are many recipes
saved, both imported or saved by the User.
Access the menu . Following screen will appear:
Use the arrow buttons to move through the lines and the Slider to scroll the specific letters. Confirm
every digit with the button . At the end press the button OK in the keyboard and confirm always
with the button . Now the display will show the filtered recipes.
ALARM CODES:
The error messages provided by the electronic control in case of operating anomalies are
listed below. When one of the following errors is displayed, with the exception of error 009 which
is self-resetting, you must contact your nearest customer service centre.
Er. 001 = the power board gives no feedback
Er. 002 = wrong firm-ware
Er. 003 = probe alarm: a probe is disconnected or short-circuited
Er. 004 = heating element anomaly
Er. 005 = program memory not working
Er. 006 = program for delayed start removed after setting
Er. 007 = blackout error: the baking could not resume after a blackout
Er. 008 = no network synchronism: the frequency of the network is unstable, or the power board is
faulty.
Er. 009 = motor thermal protection: the power board has blocked the oven because of excessive
heating of the motor. Once the anomaly is resolved, the oven returns operational.