Manual

B6TTR-B10TTR page. 63
program, press the key for 3 seconds. The program is than exported.
The display shows the writing “******” during this operation. He end of this
procedure will be underlined also by an acoustic signal. Repeat the same
procedure for all programs to be exported. To exit the menu “Export”
press the key .
The message “Operation execution error” appears in case of incorrect access to the USB memory
stick.
The message “Invalid program file” appears in case of incorrect file dimensions or if the file is
corrupted.
ALARM CODES:
The error messages provided by the electronic control in case of operating anomalies are
listed below. When one of the following errors is displayed, with the exception of error 009 which
is self-resetting, you must contact your nearest customer service centre.
Er. 001 = the power board gives no feedback
Er. 002 = wrong firm-ware
Er. 003 = probe alarm: a probe is disconnected or short-circuited
Er. 004 = heating element anomaly
Er. 005 = program memory not working
Er. 006 = program for delayed start removed after setting
Er. 007 = blackout error: the baking could not resume after a blackout
Er. 008 = no network synchronism: the frequency of the network is unstable, or the power board is
faulty.
Er. 009 = motor thermal protection: the power board has blocked the oven because of excessive
heating of the motor. Once the anomaly is resolved, the oven returns operational.