Instruction manual

Page 12
4509/4510,4512
Pivot motor to unwrap belt from motor pulley shaft.
Remove drive belt through the knife pulley opening in base casting.
Install replacement belt on knife pulley and on motor pulley shaft. DO
NOT
reinstall knife at this time.
Reinstall motor pivot rod. Tighten set screw (Figure 7 [15]).
Position the pivot rod collar (End of motor shaft should be 1/16
- 1/8" away
from base casting. If not slide motor along rod accordingly.) Tighten
collar set
screw (Figure 7 [17]),.
Align belt on motor shaft and knife pulley.
Tighten motor adjustment screw (Figure 7 [3]) until adequate belt
tension is
acquired. DO NOT over tighten. Tighten jam nut (Figure 7 [2]).
Connect electrical power cord and operate slicer to check that belt and
pulley
are running true.
Turn off slicer and disconnect electrical power cord.
Reinstall bottom cover and secure with the four suction feet.
Using caution, reinstall knife and secure wìth three
screws.
Reinstall knife guard and secure with knife guard knob.
Reinstall sharpener and secure with knob assembly.