SDS

_____________________________________________________________________________________________
1376280 - Alkaline Battery Revision Date 17-Jan-2017
of children. Protect from moisture. Store locked up. Store away from other materials.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Limits
.
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Manganese dioxide
1313-13-9
TWA: 0.02 mg/m
3
Mn respirable
particulate matter
TWA: 0.1 mg/m
3
Mn inhalable
particulate matter
(vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
Mn
IDLH: 500 mg/m
3
Mn
TWA: 1 mg/m
3
Mn
STEL: 3 mg/m
3
Mn
Zinc
7440-66-6
STEL: 10 mg/m
3
respirable
fraction
TWA: 2 mg/m
3
respirable
fraction
TWA: 5 mg/m
3
fume
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable
fraction
IDLH: 500 mg/m
3
Ceiling: 15 mg/m
3
dust
TWA: 5 mg/m
3
dust and fume
STEL: 10 mg/m
3
fume
Potassium hydroxide
1310-58-3
Ceiling: 2 mg/m
3
(vacated) Ceiling: 2 mg/m
3
Ceiling: 2 mg/m
3
Graphite
7782-42-5
TWA: 2 mg/m
3
respirable
particulate matter all forms
except graphite fibers
TWA: 15 mg/m
3
total dust
synthetic
TWA: 5 mg/m
3
respirable
fraction synthetic
(vacated) TWA: 2.5 mg/m
3
respirable dust natural
(vacated) TWA: 10 mg/m
3
total
dust synthetic
(vacated) TWA: 5 mg/m
3
respirable fraction synthetic
TWA: 15 mppcf natural
IDLH: 1250 mg/m
3
TWA: 2.5 mg/m
3
respirable
dust
Chemical name Alberta British Columbia Ontario TWAEV Quebec
Manganese dioxide
1313-13-9
TWA: 0.2 mg/m
3
TWA: 0.2 mg/m
3
TWA: 0.02 mg/m
3
TWA: 0.1 mg/m
3
TWA: 0.2 mg/m
3
Potassium hydroxide
1310-58-3
Ceiling: 2 mg/m
3
Ceiling: 2 mg/m
3
CEV: 2 mg/m
3
Ceiling: 2 mg/m
3
Graphite
7782-42-5
TWA: 2 mg/m
3
TWA: 2 mg/m
3
TWA: 2 mg/m
3
TWA: 2 mg/m
3
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992).
Appropriate engineering controls
Engineering controls
Showers
Eyewash stations
Ventilation systems.
Individual protection measures, such as personal protective equipment
Eye/face protection
Face protection shield.
Hand protection
Wear suitable gloves. Impervious gloves.
Skin and body protection
Wear suitable protective clothing. Long sleeved clothing. Chemical resistant apron.
Respiratory protection
No protective equipment is needed under normal use conditions. If exposure limits are
exceeded or irritation is experienced, ventilation and evacuation may be required.
_____________________________________________________________________________________________
Page 5 / 11