Technical data
Operation
4-42
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Motor (contd.)
Parameters (Screen 1: Type of Motor Enable,
Adaptation to Parent Machine)
NOTE: To be able to work on the parameter level, the password for level 2
(trained personnel) must first be entered.
Fig. 4-52 M2
Motor Enable Via Control Panel / Control Panel AND Standard I/O
Control panel: The Standard I/O interface signals All motors ON/OFF
(collective enable) and Enable motor are deactivated. The motors can then
only be enabled and switched on via the control panel.
In this case the melter can function even without a standard I/O connection
to the parent machine, e.g. if it is to be purged for maintenance purposes.
Enable motor via Control Panel
Line Speed Signal
Either analog or digital (pilot voltage via bus) can be selected.
Max. in Key-to-line Mode
For calibration with the signal received from the parent machine.
Example: The parent machine runs at maximum speed. An input signal of
9.8 V (actual value) is displayed. Then set Max. in key-to-line mode to 9.8
(applies only to analog signal).