Standard I/O Group Inputs
Input: An input (for enabling) can be assigned to each application group.
The desired input for the application group is selected by pressing the key
repeatedly.
Fig. 4-26 V6
No input: These application groups can not be switched via the interface
Standard I/O. These groups must be switched by the operator via the
control panel or via the field bus.
Select Feature
Deactivated: The temperature channels assigned to a deactivated
application group are not heated.
Temperature control and monitoring for faults do not take place. Exception:
Overtemperature shutdown at a set temperature value of 245 °C (475 °F).
Standby: The temperature channels in this application group are lowered
by the standby values set in the temperature parameter screen (Refer to
Fig. 4-22).