Parameters (Screen 2: Activate Channel, Mode,
Control Parameters)
NOTE: To be able to work on the parameter level, the password for level 2
(trained personnel) must first be entered.
The keys can be used to select a certain temperature zone.
Temperature Channel: Select Deactivated / Activated
Not activated (deactivated)
A deactivated channel is not heated. Temperature control and monitoring for
faults do not take place. Exception: Overtemperature shutdown at a set
temperature value of 245 °C (475 °F).
Fig. 4-24 T3
Activated
Normal state of a channel during operation. Activated channels can be
switched to display or control mode.
NOTE: Temperature channels for reservoir and grid can not be deactivated.
Not activated
Mode: Select Display Mode (Monitoring) or Control Mode
Display mode
In Display mode only the measured temperature is displayed. Temperature
control and monitoring for faults do not take place. Exception:
Overtemperature shutdown at a set temperature value of 245 °C (475 °F).
NOTE: Temperature channels for reservoir and grid as well as grouped
channels can not be switched to display mode.
Control mode
A PID control algorithm is used for the selected control parameters in
control mode.
Control mode