Technical data

Status display
0 500 h
h500
Remaining time until system
ready
0 20 min
min3
Heating hours until next
maintenance
0 500 h
h500
Heatup phase
Time until automatic enter standby
after motor stop
0 15 min
min13
0 500 h
h500
System ready
Time until automatic enter standby
after motor stop
0 15 min
min13
0 500 h
h500
Startup protection
Time until manual standby duration expires
0 10 min
min9
0 500 h
h500
Standby
Heaters off
Heating hours until next
maintenance
Heating hours until next
maintenance
Heating hours until next
maintenance
Heating hours until next
maintenance
Operation
4-4
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Status Display
Another screen is called up by touching the line Status display. The contents
of the screen is a factor of the displayed status:
S Heatup phase
S System ready
S Startup protection or standby
S Motor running or heaters off.
By status
S Warning
S Fault
S Shutdown
the system moves directly to Fault indications (Refer to Fig. 4-29).