Technical data

XS5
XS5.n
XS32.n
Installation
3-17
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Interface Key-to-line Mode
In Field bus mode (option Field bus communication) the line speed signals
are deactivated.
One Line Speed Signal Input for all Motors
XS5
Pin Input Function
1 (Ground) Analog input
2 0 to 10 V
Pin 3 to 5 not assigned
Fig. 3-13
Separate Line Speed Signal Inputs
XS5.1 to XS 5.2 (3-pin)
Pin Input Function
1 (Ground) Analog input
2 0 to 10 V
DC
Pin 3 not assigned
Fig. 3-14
Interface Air run-up
XS32.1 to 32.16
Pin Output Function
1 24 V Analog output
2 0 to 10 V
3 (Ground)