Technical data

2
1
Installation
3-9
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Connecting Filling Valve (Option)
Conditioning Compressed Air
The quality of the compressed air must be at least class 2 in compliance
with ISO 85731. This means:
S Max. particle size 30 mm
S Max. particle density 1 mg/m
3
S Max. pressure dew point 40 °C
S Max. oil concentration 0.1 mg/m
3
.
1. Connect customer’s compressed air supply to the control air connection
(2).
4 to 6 bar 400 to 600 kPa 58 to 87 psi
2. Electrically/mechanically connect hose to the filling unit.
3. Connect hose to filling valve connection (1) (Refer to illustration).
The filling valve is heated either via the VersaBlue melter or via the filling
unit (e.g. bulk melter).
4. If heating does not occur via the VersaBlue melter, insert the electrical
plug (cordset) into the hose receptacle.
Fig. 3-11