Technical data
Introduction
2-3
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Definition of Terms
Interface Standard I/O
Component designation: XS 2
Transmits the digital input and output signals between the parent machine
and the Nordson melter.
Interface Key-to-line Mode
Component designation: XS 5 (one line speed signal input for all motors)
XS 5.1, XS 5.2, XS 5.3 and XS 5.4 (option: separate line speed signal
inputs).
NOTE: Key-to-line is also referred to as Automatic mode in Nordson
literature.
In key-to-line the motor/pump speed is regulated synchronously to the
speed of the parent machine.
The types described in this manual can be operated in key-to-line mode
with a line speed voltage of 0 − 10 V
DC
.
Encoder
The encoder compiles the line speed of the parent machine. It supplies a
certain number of electrical pulses per revolution. The frequency is a
measure of line speed.
CAUTION: The cable length may not be modified; this could cause
incorrect evaluation of the line speed, resulting in incorrect material
applications.
Symbols
Nordson default
Reset