Technical data

Index Protocols and Communication Data List
B-32
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Data
index
Data designation Channel
number
Setting range,
resolution
Temperature
110 Temperature unit 0 0 / 1 0
0:
°Celsius
1:
°Fahrenheit
111
1)
Activate/deactivate temperature channel 3 54 0 / 1 0
0: Deactivate
1: Activate
112 Switch application group*) 1 8 0 / 1 0
*) Standby or Deactivate is dependent on the function
selected on the control panel.
Falling edge: Switch application group to standby or
0
1
Falling edge: Deactivate application group
0
1
Rising edge: Switch application group to control mode
0
1
113
2)
Temperature channel control mode / display mode 3 54 0 / 1 0
0: Control mode
1: Display mode
114 Status: Temperature channel 1 54 0 4
[R]
0: Switched off
1: Deactivated
2: Display mode
3: Control mode
4: Standby
115 Temperature setpoint 1 54
Min: 40 °C (100°F)
*)
*) Grid and reservoir: 175 °C
Hose1 and gun1: 175 °C (deactivated)
All other channels: 40 °C (deactivated)
Max. standard:
230 °C (450°F)
Max HT:
250 °C (480°F)
1)
NOTE on data index 111: A channel that is part of a group can not be activated/deactivated with this
index.
2)
NOTE on data index 113: A channel that is part of a group can not be switched from control mode to
display mode.