Technical data

Index Protocols and Communication Data List
B-31
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Data
index
Data designation Channel
number
Setting range,
resolution
Pressure
82 Motor control data 1 Bit field
Bit 11 1 Pressure build-up feature motor 12
enabled
0 Pressure build-up feature motor 12
not enabled
0
Bit 12 1 Pressure build-up feature motor 13
enabled
0 Pressure build-up feature motor 13
not enabled
0
Bit 13 1 Pressure build-up feature motor 14
enabled
0 Pressure build-up feature motor 14
not enabled
0
Bit 14 1 Pressure build-up feature motor 15
enabled
0 Pressure build-up feature motor 15
not enabled
0
Bit 15 1 Pressure build-up feature motor 16
enabled
0 Pressure build-up feature motor 16
not enabled
0
83 Pressure build-up feature
Line speed value for activating pressure build-up
1 16 0 95 % 10 %
84 Pressure build-up feature
Setpoint for pressure build-up (only sensor A)
1 16 1 70 % of pres-
sure measuring
range end value