Technical data
Index Protocols and Communication Data List
B-25
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Data
index
Data designation Channel
number
Setting range,
resolution
Motor
37 Motor OFF delay 1 − 14 0 − 30 s 0
38 Status: Motor OFF delay 1 − 14 0 / 1 −
[R]
0: Motor OFF delay not operating
1: Motor OFF delay operating
39 Key-to-line
Line speed for min. pump speed (index 35) or for
min. pressure (index 81).
1 − 14 0.0 − 100.0 % 0.0
40-42 Reserved
43 Activate/deactivate threshold switch 1 − 14 0 / 1 0
0: Deactivate
1: Activate
44 Upper threshold value 1 − 14 1.0 − 100.0 % 10.0
45 Lower threshold value 1 − 14 1.0 − 100.0 % 5.0
46 Reserved
47 Motor status and alarms 1 − 14 Bit field −
[R]
Bit 0 Value: 1 Motor running
0 Motor not running
Bit 1 Value: 1 Alarm: Motor coupling blocked or
phase missing (shutdown)
0 No alarm
Bit 2 Reserved
Bit 3 Value: 1 Alarm: Motor or motor controller has
overtemperature (fault)
0 No alarm
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved