Technical data
Index Protocols and Communication Data List
B-12
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Bit Value Action
Standard Extended
Status Status 1 Status 2
− − 4 1 Motor 5 running (if there is a motor 5)
0 Motor 5 not running
− − 5 1 Motor 6 running (if there is a motor 6)
0 Motor 6 not running
− − 6 1 Motor 7 running (if there is a motor 7)
0 Motor 7 not running
− − 7 1 Motor 8 running (if there is a motor 8)
0 Motor 8 not running
− − 8 1 Motor 9 running (if there is a motor 9)
0 Motor 9 not running
− − 9 1 Motor 10 running (if there is a motor 10)
0 Motor 10 not running
− − 10 1 Motor 11 running (if there is a motor 11)
0 Motor 11 not running
− − 11 1 Motor 12 running (if there is a motor 12)
0 Motor 12 not running
Command
The master has to send a Command to the Nordson melter. Every
Command is defined by a job identification.
Job identification Function
1
dez
No job for the Nordson melter
3
dez
The master wishes to read data
from the Nordson melter
6
dez
The master wishes to write data to
the Nordson melter
All other job identifications are invalid and generate an index protocol error
in Status.