Technical data

Index Protocols and Communication Data List
B-11
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Status (contd.)
Bit Value Action
Standard Extended
Status Status 1 Status 2
9 1 Control mode: Standard
0 No standard mode
10 1 Control mode: Field bus
0 No field bus mode
11 1 Control mode: Dual
0 No dual mode
14 14 1 Index protocol error:
Incorrect Command received
Incorrect Data index received
Incorrect Channel number received
0 No index protocol error
15 15 1 Communication data fault in the Data value or Line speed value
Data values can not be changed.
Example: Write job for actual values.
Data access not permitted.
Example: Write jobs in Standard mode or jobs for channels
that are not installed.
The data value or at least one line speed signal value is
invalid. The data block received may not be evaluated by
the master.
Example: A value is outside of the permitted value range.
0 No communication data fault
7 0 1 Motor 1 running
0 Motor 1 not running
8 1 1 Motor 2 running (if there is a motor 2)
0 Motor 2 not running
9 2 1 Motor 3 running (if there is a motor 3)
0 Motor 3 not running
10 3 1 Motor 4 running (if there is a motor 4)
0 Motor 4 not running
Continued ...