Technical data

Index Protocols and Communication Data List
B-8
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Protocol Data
Melter Control
With Melter control, control signals are transmitted with every transmission
data block that the Nordson melter processes, regardless of what was
entered by Command.
NOTE: Empty or reserved bits must be set to 0 (zero).
Bit Value Action
Standard Extended
Melter
control
Melter
control 1
Melter
control 2
0 0
0
1
Heaters ON
0
1
Heaters OFF
1 1 1 All motors ON (collective enable)
0 All motors OFF
2 1 Line started
0 Line stopped
6 3
0
1
Enter standby
0
1
Exit standby
7 4
0
1
Key-to-line mode (for all motors)
0
1
Manual mode (for all motors)
2 0 1 Enable motor 1
0 No motor 1 enable
3 1 1 Enable motor 2 (if there is a motor 2)
0 No motor 2 enable
4 2 1 Enable motor 3 (if there is a motor 3)
0 No motor 3 enable
5 3 1 Enable motor 4 (if there is a motor 4)
0 No motor 4 enable
Continued ...