Technical data
Index Protocols and Communication Data List
B-6
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Transmission Data Block (Extended) (contd.)
N + 12 Word Line speed value for motor 1 (key-to-line mode)**
** The value to be transmitted is always multiplied by the factor 10.
N + 14 Word Line speed value for motor 2 (key-to-line mode)**
N + 16 Word Line speed value for motor 3 (key-to-line mode)**
N + 18 Word Line speed value for motor 4 (key-to-line mode)**
N + 20 Word Line speed value for motor 5 (key-to-line mode)**
N + 22 Word Line speed value for motor 6 (key-to-line mode)**
N + 24 Word Line speed value for motor 7 (key-to-line mode)**
N + 26 Word Line speed value for motor 8 (key-to-line mode)**
N + 28 Word Line speed value for motor 9 (key-to-line mode)**
N + 30 Word Line speed value for motor 10 (key-to-line mode)**
N + 32 Word Line speed value for motor 11 (key-to-line mode)**
N + 34 Word Line speed value for motor 12 (key-to-line mode)**
Other words Reserved
NOTE: The communication data is transmitted in Intel format, i. e. the low byte of a word is placed on the
lowest address and the high byte on the highest address.
Receive data block (extended)
Byte address Format Designation
N Word Status 1
Bit 0: System ready
Bit 1: Startup protection
Bit 2: General alarm −warning−
Bit 3: General alarm −fault−
Bit 4: Shutdown
Bit 5: Heatup phase
Bit 6: Standby
Bit 7: Fill tank
Bit 8: Heaters OFF/ON
Bit 9: Control mode: Standard
Bit 10: Control mode: Field bus
Bit 11: Control mode: Dual
Bit 12: Reserved
Bit 13: Reserved
Bit 14: Index protocol error
Bit 15: Communication data fault
Continued ...