Technical data
Maintenance
5-15
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Cleaning Filter Cartridge
1. Disassemble the filter cartridge.
2. Use a cleaning agent to remove any material residue that can not be
removed mechanically.
3. Always follow the manufacturer’s instructions when using cleaning
agents!
5
22
7
4
Size 16
6
1
3
2
Size 13
Size 24
Fig. 5-14
1 Filter screw
2 O-ring
3 Thread
4 Filter sheath
5 Filter screen
6 Nut
7 Hexagon nut (locknut)
Assembling Filter Cartridge
1. Clamp the filter screw vertically in a vice.
2. Carefully inspect O-rings; replace if necessary.
3. Assemble the individual parts (Refer to illustration above).
4. Screw the nut (6, Fig. 5-14) onto the thread (3, Fig. 5-14) by hand. Use
caution to prevent the filter screen from jamming.
5. Tighten with a torque wrench (size 16).
Torque 14 Nm / 124 lbin.
6. Secure with a locknut; use a torque wrench (size 13).
Torque 24 Nm / 212 lbin.
NOTE: Nordson recommends using an second wrench to brace the nut
and prevent it from turning.
Fig. 5-15