Technical data

Maintenance
5-3
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Melter part Activity Interval Refer to
Air hoses Inspect for damage Every time the melter is serviced
Gear pump
Replace VarisealR
When material escapes from the
pump shaft
5-9
Tighten the gland bolt After initial startup 5-10
Check for leakage,
tighten gland bolt if nec-
essary
Dependent on hours of
operation, pump speed and
pump temperature
Recommendation: Monthly
5-10
Tighten fixing screws Every 500 hours of operation 5-10
Motor / gear box Change lubricant Every 15000 hours of operation
or every 2 to 3 years
5-11
Clean fan cover Depending on dust
accumulation; daily if necessary
Pressure control valve Replace outer O-rings
(service kit)
At the latest when leakage
occurs
5-12
Disassemble and clean Every six months
Filter cartridge Replace filter cartridge
Disassemble and clean
filter cartridge
Depending on degree of material
pollution
Recommendation: Every 1000
hours of operation
5-14
Safety valve plate Replace O-rings (service
kit)
When the safety valve plate is
detached, at the latest when
leakage occurs
5-17
Tank isolation valve Replace O-ring (service
kit)
When the tank isolation valve is
detached, at the latest when
leakage occurs
5-18
Pneumatic safety valve Performance check;
clean or replace if
necessary
Every six months 5-19
Pressure sensor Calibrate Once/year, more often when
conditions dictate
Section
Operation
Check separating
membrane for damage
Every time pressure sensor is
removed, more frequently if
necessary
Check whether
hardened or charred
material is stuck to the
membrane; clean
separating membrane if
necessary
Every time pressure sensor is
removed, more frequently if
necessary
5-20