Installation manual

2/56
2
2.3
Characteristics
Modicon TSX Micro
automation platform 0
Power supplies for d.c. control circuits
Phaseo regulated switch mode power supplies
Technical characteristics
Type of power supply ABL-7CEM ABL-7RE ABL-7RP
Product certifications
cULus, TÜV UL, CSA, TÜV, CTick
Conforming to standards
UL 508 UL 508, CSA 22.2 n° 950
Safety
IEC/EN 60950 IEC/EN 61496-1-2
EMC
EN 50081-2, EN 50082-2 EN 50081-1, IEC 61000-6-2 (EN 50082-2)
Low frequency harmonic currents
EN 61000-3-2
Input circuit
LED indication Orange LED Orange LED
Input voltages Rated values
V a 100…240,
c 110…220 compatible (1)
a 100…240 a 100…240,
c 110…220 compatible (1)
Permissible values
V a 85…264,
c 105…370 compatible (1)
a 85…264 single-phase a 85…264,
c 100…250 compatible (1)
Permissible frequencies
Hz 47…63
Efficiency at nominal load > 70 % > 85 %
Current
consumption
Ue = 240 V A 0.1 (7 W)/0.2 (15 W)/0.45
(30 W)
0.6 (48 W)/0.83 (72 W)
1.2 (120 W)/2.5 (240 W)
0.4 (72 W)/0.6 (120 W)
1.3 (240W)
Ue = 100 V
A 0.17 (7 W)/0.3 (15 W)/0.68
(30 W)
1.2 (48 W)/1.46 (72 W)
1.9 (120 W)/3.6 (240 W)
0.8 (72 W)/1 (120 W)/2.8
(240 W)
Current at switch-on
A < 50 < 30
Power factor 0.45 approx. 0.65 approx. 0.98 approx.
Output circuit
LED indication Green LED Green LED Green LED
Nominal output voltage (U out)
V c 24 12, 24 and 48
Nominal output current
A 0.3/0.6/1.2 2/3/5/10 2.5/5/10
Precision Output voltage
Adjustable from 90 to 110 % Adjustable from 100 to 120 %
Line and load regulation
2 % max ± 3 %
Residual ripple - interference mV < 200 (peak-peak)
Micro-breaks Holding time at I max and Ve min
ms > 20 > 10 > 20
Temporary overloads Permissible inrush current (U out >19V)
See curves page 2/59
Protection Short-circuit
Permanent/automatic
restart
Permanent/automatic
restart
Permanent/automatic
restart or restart after
switching off mains power
Overload
1.05 In 1.1 In
Overvoltage U > 1.2 Tripping if U > 1.5 Un
Undervoltage
Tripping if U < 0.8 Un
Operating and environmental characteristics
Connections Input mm
2
2 x 2.5 + earth
Output
mm
2
2 x 2.5 2 x 2.5 + earth, multiple output, depending on model
Ambient conditions Storage temperature
°C - 25… + 70
Operating temperature
°C - 10… + 60 (derating as
from 50° C, mounted
vertically)
0… + 60 (derating as from 50° C, mounted vertically)
Max. relative humidity
20…90 % 95 % without condensation or dripping water
Degree of protection
IP 20 conforming to IEC 529
Vibrations
Conforming to IEC 61131-2
Operating position
Vertical and horizontal
(see derating curve,
page 2/58)
Vertical
MTBF at 40°
> 100 000 h
Connections Series
Possible (see page 2/59)
Parallel
No Possible (max. temperature 50° C)
Dielectric strength Input/output
3000 V/50 and 60 Hz 1 min 3000 V/50 and 60 Hz 1 min
Input/earth
2000 V/50 and 60 Hz 1 min 3000 V/50 and 60 Hz 1 min
Output/earth (and output/output)
500 V/50 and 60 Hz 1 min 500 V/50 and 60 Hz 1 min
Input fuse incorporated
Yes (not interchangeable)
Disturbance
EN 50081-2 (generic) EN 50081-1
Conducted
EN 55011/EN 55022 class A
(7 and 15 W) EN 55011/EN
55022 class B (30W)
EN 55011/EN 55022 class B
Radiated
EN 55011/EN 55022 class B
Immunity
IEC 61000-6-2 (generic)
Electrostatic discharge
EN 61000-4-2 (4 kV contact/8 kV air)
Electromagnetic
EN 61000-4-3 level 3 (10 V/m)
Conducted interference
EN 61000-4-4 level 3 (2 kV) , EN 61000-4-5, EN 61000-4-6 level 3, EN 61000-4-8 level 4
Mains interference
EN 1000-4-11 (voltage drops and cuts)
(1) Compatible input voltage, not indicated on the product.
resentation :