Modicon TSX Micro
automation platform 0
Safety automation system solutions
Preventa safety module type TSX DPZ
The TSX DPZ 10D2A Emergency stop monitoring module integrated into the
TSX Micro PLC combines:
b The ease of use of Preventa safety modules.
b PLC diagnostics performance.
It also maintains all the advantages of a standard PLC (extended choice of I/O, ease
of installation, flexibility of hardware and software developments, etc).
The TSX DPZ 10D2A Emergency stop monitoring module combines a Preventa
(XPS) hard-wired safety relay and a discrete acquisition function in a half-slot, for full
diagnostics of input contacts and the state of safety circuit outputs.
The TSX DPZ 10D2A safety module is used to interrupt one or more Emergency or
safety stop control circuits in complete safety, in accordance with EN 60204-1.
The proven safety of hard-wired technology and the capacity of the TSX Micro PLC
make module TSX DPZ 10D2A the optimum solution for making machines more
reliable, safer, more compact and more cost-effective.
LModule TSX DPZ 10D2A is suitable for Emergency stop and limit switch monitoring
applications, requiring a level of safety up to category 3 (1) according to EN 954-1
(safety related parts of control systems).
(1) For more information on control system safety categories, please consult our specialist
catalogue “Preventa safety solutions”.
Emergency stop monitoring module TSX DPZ 10D2A comprises:
1 A metal casing with a locking system for fixing the module in its slot. This system
is only accessible when the screw terminal block is removed.
2 A removable screw terminal block for connecting sensors and preactuators.
3 A cover giving access to the screw terminal block, which also holds the marker
legend.
Presentation
Application developments requiring safety systems and PLC diagnostics
Description
K3
K4
Safety
relay
TSX Micro
S
olution with safety relay and separate PLC
K3
K4
TSX Micro + TSX DPZ
S
implification using the safety module integrated in the PLC