Installation manual

2/12
2
2.1
Characteristics (continued)
Modicon TSX Micro
automation platform 0
Discrete I/O modules
(1) Characteristics at 60 °C for 60 % I/O loading or at 30 °C for 100 % I/O loading.
(2)For 0.1 x 10
6
operations.
(3)For 0.15 x 10
6
operations.
(4)For 0.2 x 10
6
operations.
(5)For 0.25 x 10
6
operations.
(6)For 0.3 x 10
6
operations.
(7)For 0.5 x 10
6
operations.
(8)For 0.7 x 10
6
operations.
(9)For 0.8 x 10
6
operations.
(10) For 1 x 10
6
operations.
(11) For 1.2 x 10
6
operations.
(12) For 1.5 x 10
6
operations.
(13) For 2 x 10
6
operations.
(14) For 3 x 10
6
operations.
(15) For 5 x 10
6
operations.
(16) For 10 x 10
6
operations.
Characteristics of relay outputs (connection via screw terminal block)
(1)
Type of modules TSX DSZ
08R5
TSX DMZ
28DR
TSX DMZ 28AR TSX DSZ 32R5
Number of outputs
8 12 12 32
Operating limit values a
V 19…264
c
V 10…34
Type of contact
NO
Thermal current
A 3 (5 A max. per common of each group of
channels)
2 ( 7 A max. per common of each group of 16
channels
a.c. load Resistive AC-12 Voltage
V 24 48 110 220 24 48 110…120 200…240
Power
VA 50 (8) 50 (10)
110 (7)
110 (10)
220 (7)
220 (10) 50 (6) 100 (5) 200 (4) 200 (6)
Inductive AC - 14
and AC - 15
Voltage
V 24 48 110 220 24 48 110…120 200…240
Power
VA 24 (7) 10 (15)
24 (13)
10 (16)
50 (12)
110 (3)
10 (16)
50 (14)
110 (10),
220 (2)
24 (2) 50 (2) 10 (9)
50 (3)
10 (11)
50 (5)
d.c. load Resistive DC-12 Voltage
V 24 24
Power
W 24 (1 x 10
6
cycles of operations)
40 (0.3 x 10
6
cycles of operations)
12 (0.5 x 10
6
cycles of operations)
24 (0.3 x 10
6
cycles of operations)
48 (0.15 x 10
6
cycles of operations)
Inductive DC - 13
(L/R = 60 ms)
Voltage
V 24 24
Power
W 10 (2 x 10
6
cycles of operations)
24 (1 x 10
6
cycles of operations)
6 (0.12 x 10
6
cycles of operations)
12 (0.06 x 10
6
cycles of operations)
24 (0.03 x 10
6
cycles of operations)
Response time Activation
ms < 10
Desactivation
ms < 10
Built-in
protection
Against short-circuits and overloads
None, obligatory mounting of a fast blow fuse per channels or groups of channels
Against inductive overvoltages in a
None, obligatory parallel mounting of a RC circuit or an MOV (ZNO) peak limiter appropriate to
the voltage
Against inductive overvoltages in c
None, obligatory mounting of a flywheel diode on the terminals of each preactuator
Consumption
See page 6/4
Type of modules
TSX DSZ
08R5
TSX DMZ
28DR
TSX DMZ 28AR TSX DSZ 32R5
Dissipated power per module
W 1.5 4.5 5.6 3.5
Isolation (test
voltage)
Between outputs and ground
V rms 2000 - 50/60 Hz for 1 minute
Between outputs and internal logic
V rms 2000 - 50/60 Hz for 1 minute
Insulation resistance
M > 10 at c 500 V
eferences:
ages 2/13 and 2/14
Connections:
pages 2/15 to 2/17
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
efesotomasyon - telemecanique inverter