Installation manual
6/6
6
Modicon TSX Micro
automation platform 0
Standards, certifications and environment
conditions
Modicon TSX Micro PLCs have been developed to conform to the principal national
and international standards concerning electronic equipment for industrial
automation systems.
b Requirements specific to programmable controllers: functional characteristics,
immunity, resistance, safety, etc.: IEC 61131-2, CSA 22.2 N° 142, UL 508.
b Merchant navy requirements of the main international bodies: ABS, BV, DNV, GL,
LR, RINA, RMRS, etc.
b Compliance with European Directives:
v Low Voltage: 73/23/EEC amendment 93/68/EEC,
v Electromagnetic Compatibility: 89/336/EEC amendments 92/31/EEC and 93/68/
EEC.
b Electrical qualities and self-extinguishing capacity of insulating materials:
UL 746C, UL 94.
b Hazardous areas classification: CSA 22.2 No. 213 Class I, Division 2 II , groups A,
B, C and D .
TSX Micro PLCs meet the requirements of "TC" treatment (
Treatment for all
Climates
).
For installations in industrial production workshops or environments corresponding
to "TH" treatment (Treatment for Hot and humid environments), TSX Micro PLCs
must be embedded in envelopes with a minimum IP 54 protection, in compliance with
IEC 60664 and NF C 20 040.
TSX Micro PLCs themselves offer
protection to IP 20 level
(1).
They can therefore
be installed without an envelope in reserved-access areas which do not exceed
pollution level 2 (control room with no dust-producing machine or activity). The
pollution level 2 does not take account of more severe environmental conditions: air
pollution by dust, smoke, corrosive or radioactive particles, vapours or salts, attack
by fungi, insects, ...
Where:
Un: nominal voltage
Fn: nominal frequency
Udl: detection level when powered
(e): tests required by European directives
e
and based on IEC / EN 61131-2 standards.
(5) In the case where a position is not occupied by a module, a TSX RAZ 01 protection cover
must be installed.
(6) Devices must be installed and wired in compliance with the instructions provided in the
TSX DG KBL E manual "Electromagnetic compatibility of networks and field buses".
Standards and certifications
Characteristics
Service conditions and recommendations relating to environment
Temperature Operation
° C 0...+ 60 (to IEC 61131-2, + 5...+ 55)
0...+ 70 with TSX FAN fan modules
Storage
° C -25...+ 70 (according to IEC 61131-2)
Relative humidity Operation
% 10…95 without condensation
Storage
% 5…95 without condensation (according to IEC 61131-2)
Altitude
m 0…2000
Supply voltage
TSX 37 10/21/22 1pp TSX 37 05/08/10/21/22 0pp
Nominal voltage
V c 24 a 100...240
Limit voltages
c 19..30 a 90...264
Nominal frequencies
Hz – 50/60
Limit frequencies
Hz – 47/63
Protective treatment of Modicon TSX Micro PLCs
Environment tests
Name of test Standards Levels
Immunity to LF interference (e) (2)
Voltage and frequency variation IEC/EN 61131-2 0.85 Un/0.95 Fn for 30 minutes; 1.15 Un/1.05 Fn for 30 minutes;
0.8 Un/0.9 Fn for 5 seconds; 1.2 Un/1.1 Fn for 5 seconds
Direct voltage variation IEC/EN 61131-2
0.85 Un...1.2 Un for 30 minutes with 5% ripple (peak values)
Harmonic 3 IEC/EN 61131-2
10 % Un; 0°/5 min...180°/5 min
Short momentary interrupt IEC/EN 61131-2
10 ms with a supply; 1 ms with c supply
Voltage shut-down/start-up IEC/EN 61131-2
Un-0-Un; Un for 60 s; 3 cycles separated by 10 s
Un-0-Un; Un for 5 s; 3 cycles separated by 1 to 5 s
Un-0.9-Udl; Un for 60 s; 3 cycles separated by 1 to 5 s
Standards and
certifications