Installation manual

5/28
5
Presentation,
description,
functions
Modicon TSX Micro
automation platform 0
FTX 117 Adjust terminal
The FTX 117 Adjust pocket terminal is used for adjusting Nano/Micro/Premium
PLCs. It is used to:
b Read, modify and force valid parameters.
b Save and retrieve PLC object lists.
b Up/down load programs and PLC data (one program and up to 10 data files per
protected RAM memory PCMCIA card).
The PLC provides the power supply to the FTX 117 Adjust terminal.
The front panel of the FTX 117 Adjust terminal comprises:
1 A connector for connecting a T FTX CB1 020 cable to the PLC.
2 A back-lit screen with 4 lines of 16 alphanumeric characters.
3 A keypad with 35 keys.
4 A slot for the type 1 PCMCIA memory card.
5 Magnets on the rear of the terminal which are used to keep it in a vertical position
on a metal support.
6 A carrying strap.
All functions can be easily accessed at any moment using 7 editors with the following
menus:
b TSX: has menus for:
v displaying the type of PLC,
v modifying/displaying the PLC operating mode: RUN/STOP/ERR,
v naming the application and the presence of forced bits,
v module diagnostics,
v setting the internal clock of the PLC.
b DAT: data editor used to:
v access all variables in real-time display,
v modify or force valid variables,
v access to the modification and display of Grafcet steps,
v convert word objects into Hexadecimal, ASCII, decimal or binary code.
b DT-i: object list editor used to:
v display or modify a list of 16 variables,
v store and retrieve an object list (63 lists maximum),
v This function requires a PCMCIA card.
b Frc: editor to find forced bits is used to:
v find and display forced bits in the PLC.
b FTX: terminal editor is used to:
v show the terminal versio,
v select the language (English, French, German, Italian Spanish),
v adjust a beep sound and lighting.
b Adr: connection editor used to access PLCs connected to the UNI-Telway bus
(master or slave).
b Trf: transfer editor requiring a PCMCIA RAM memory card. Used for transfers from
PLCs to the PCMCIA card and vice versa, a program and one or more %MWi data
files (up to 10 data files) via the FTX 117 terminal.
Presentation
Description
1
2
3
5
4
6
Functions
TSX 0720-10
RUN ERR I/O
APP : Exec f
Mod0=OK
Example of DAT editor
%IW0.0 0
%IW0.0 0
%IW0.1 200
%IW0.0 0
Transfer list
Format Card
ADJ (max 62) :
Example of Frc editor
%Q00 1f
End of list
eferences:
age 5/29
Encombrements:
page 5/29
Example of TSX editor
Example of DT-i editor
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
efesotomasyon - telemecanique inverter