Installation manual

5/16
5
Characteristics
Modicon TSX Micro
automation platform 0
PL7 Micro/Junior/Pro programming software
b 64/255 Timers: %TMi (0 i 254) 10 ms to 9999 ms
b 32/255 Up/Down counters: %Ci (0 i 254) 0 to 9999 (word)
b 64/255 Timers PL7-2: %Ti (0 i 254)
b 8/255 Monostables: %MNi (0 i 254) 16 steps
b 4/255 LIFO or FIFO 16 bit registers: %Ri (0 i 254)
b 8/255 Drums: %DRi (0 i 254) 16 steps
b The total number of timers %TMi and %Ti is limited to 64/255
b Instructions on word and double word tables.
b Logical instructions on words and double words.
b Arithmetic instructions on words and double words.
b Instructions on floating point words.
b Instructions on bit tables.
b Character string instructions.
b Binary conversion instructions.
b Time management instructions.
b Logarithmic and exponential instructions.
b Trigonometric instructions.
b Instructions on program.
(1)Function requiring PL7 Junior/Pro software.
(2) If the maximum number of objects are not specified in this table, consult our Modicon Premium
automation platform catalogue.
(3) 1024 step bits and macro-step step bits.
Functions and instructions
Predefined function blocks (1)
Type of PL7 instructions
Addressable objects (2)
Bit objects Word objects
b %I/Qx.i: I/O module inputs/outputs
b %Mi: internal bits
b 256 on TSX Micro TSX 37,
b 3692 on TSX P57 1p3M,
b 8056 on TSX P57 2p3M/T PCX 57 203M
b 16248 on TSX P57 3p3M/453M and
T PCX 57 353M
b %Si: 128 bit system
b %Xi: Grafcet step bits
b 96 on TSX Micro TSX 37-10,
b 128 on TSX Micro TSX 37-21/22
b 1024 (3) on Premium
b %XMj: 64 macro-step bits on Premium
PLC
b %…i.j.: function block bits
b %…i.Xk: bits extracted from internal words,
systems, constants, from I/O, common
networks
b %MWi, %MDi, %MFi: single length internal
words, double length, floating
b %KWi, %KDi, %KFi: single length constant
words, double length, floating
b %IWi.j/%QWi.j: module I/O words
b %SWi: 128 system words
b %NWi: common words on the network
b %MBi:L, %KBi:L: character string
b %…i.j: function block words
b %…i[%MWi]: indexed objects (I/O bits,
constant internal words)
Indexed objects Structured objects
b %i[%MWj]: bits (inputs, outputs and
internal)
b %Mpi[%mWj]: internal words,
(single/double length and floating)
b %Kpi[%mWj]: constant words (single and
double length and floating point)
b %MWi[MWj]: table of internal words
b %Mi:L: bits string (I/O, internal and Grafcet
bits)
b %ppi:L: constant internal words (single or
double length, floating and words system)
b %pBi:L: character string (internal words
and constants)
resentation:
age 5/5
Setup, language:
pages 5/6 to 5/11
Functions:
pages 5/12 to 5/15
Reference:
pages 5/17 to 5/19
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
efesotomasyon - telemecanique inverter