Installation manual
4/65
4
4.4
References
Modicon TSX Micro
automation platform
Asynchronous serial links
References
Asynchronous serial link elements (character mode)
Description Protocol Physical layer PLC Reference
(1)
Weight
kg
Integrated link on
processor
Character mode
Uni-Telway
RS 485
non-isolated
TSX Micro See page 1/15 –
Premium Consult our catalog
”Modicon Premium
automation platform”
–
Atrium Consult our catalog
”Modicon Premium
automation platform”
–
Communication module Character mode
Uni-Telway
Modbus/Jbus
- 1 isolated RS 485
integrated chan.
(channel 0),
- 1 type III PCMCIA
card slot (channel 1)
(2)
Premium
Atrium
TSX SCY 21601 –
Type III PCMCIA cards for
TSX 37 21/22, PLC,
TSX/PCX Premium
processor or
TSX SCY 21601 module
Character mode
Uni-Telway
Modbus/Jbus
RS 232 D (9 signaux)
0,3…19,2 K bits/s
TSX SCP 111 –
RS 485 (compatible RS 422)
1,2…19,2 K bits/s
TSX SCP 114 –
BC 20 mA
1,2…19,2 K bits/s
TSX SCP 112 –
Asynchronous serial link connection accessories
Description Use Length Reference Weight
kg
Terminal port connection
box
Isolation of RS 485 signals, end of line
adaptation, supplied with cable for
connection to PLC
1 m TSX P ACC 01 0.690
Connecting cables for asynchronous serial links
Description Use
From
To
Length Reference Weight
kg
Cables for isolated RS 485
connection
TSX SCP 114 card RS 485/RS 422
device
(3)
3 m TSX SCP CX 4030 0.160
Integrated channel
(channel 0) module
TSX SCY 21601
RS 485/RS 422
device (4) via
TSX SCA 50 box
3 m TSX SCY CU 6030 0.180
Universal cable for
terminal port/RS 232
device
TSX Micro/Premium/
Atrium port
(TER or AUX) or
TSX P ACC 01 box
RS 232D of a
terminal device (DTE)
(5)
2.5 m TSX PCX 1031 0.170
USB port of PC 2.5 m TSX PCX 3030 –
Cables for RS 232D
connection
TSX SCP 111 card Communication
device: modem,
converter, (DCE)
(4)
3 m TSX SCP CC 1030 0.190
Point-to-point
terminal device (DTE)
(4)
3 m TSX SCP CD 1030 0.190
10 m TSX SCP CD 1100 0.620
Cable for BC 20 mA
connection
TSX SCP 112 card Current loop device
(3)
3 m TSX SCP CX 2030 0.160
(1) Product supplied with a bilingual Quick Reference Guide: English and French.
(2) PCMCIA type III slot can receive one TSX SCP 111/112/114, TSX FPP 20 or
TSX JNP 112/114 card.
(3) End of cable fitted with flying leads.
(4) End of cable fitted with a 25-way male SUB-D connector.
(5) End of cable fitted with a 9-way male SUB-D connector. For use, to order separatly one
TSX CTC 10 adaptator (9-way male SUB-D connector/25-way male SUB-D connectors).
P
remium
T
SX Micro
T
SX SCY 21601
T
SX SCP 11
p
T
SXPACC 01
T
SX PCX 1031
P
resentation:
p
age 4/58
Description:
page 4/58
Characteristics:
page 4/58