Installation manual
4/36
4
4.3
Connections
Modicon TSX Micro
automation platform 0
Modbus Plus network
1 TSX MBP 100: Modbus Plus PCMCIA card, for type III processor slot on TSX Micro
or Premium platforms.
2 170 PNT 110 20: communication module for Momentum I/O base unit.
3 490 NAA 271 0p: trunk cable, shielded twisted pair with shielding drain (flying
leads). In lengths of 30, 150, 300, 450 or 1,500 m.
4 170 MCI 020/021 pp: drop cable equipped at each end with an RJ45 connector
(baseT interface). In lengths of 0.25, 0.75, 3 or 10 m.
5 990 NAD 230 00: IP 20 local site tap, provides a tap link from the trunk cable for
connecting 1 device (connection of conductors requires wiring tool 043 509 383).
Integrates the line terminal.
6 990 NAD 230 10: IP 65 zamac local site tap, provides a tap link from the trunk
cable for connecting 1 device (screw terminal connection). It also has an RJ45
connector for connecting a programming and maintenance terminal.
7 170 XTS 020 00: IP 20 tee, provides a tap link from the Modbus Plus cable (cable
with connectors at each end of an RJ45 connector). It has a 9-way SUB-D female
connector for connecting the device.
8 TSX MBP CE 030/060: drop cable for Modbus Plus PCMCIA card, equipped on
the PCMCIA side with a 20-way miniature connector and with flying leads on the
990 NAD 230 00/010 local site tap side. In lengths of 3 or 6 m.
9 990 NAD 211 10/30: drop cable equipped on the device side with a 9-way SUB-D
male connector and with flying leads on the 990 NAD 230 00/010 local site tap
side. In lengths of 2, 4 or 6 m.
10TSX MBP CE 002: drop cable for Modbus Plus PCMCIA card, equipped on the
PCMCIA side with a 20-way miniature connector and on the network side with a
9-way SUB-D female connector. Can be used as an extension for cable
990 NAD 211 10/30. In lengths of 0.2 m.
11
AS MBKT 185:
set of 2 line terminators (impedance adapter)
to be placed at
each end of the segment. The AS MBKT 185 terminators are placed directly at the
end of the cable (without a tap or tee).
990 NAD 230 11: set of 2 line terminators (impedance adapter) for IP 65 local site
tap 990 NAD 230 10, to be placed at each end of the segment.
12170 XTS 021 00: set of 2 line terminators (impedance adapter) for tee
170 XTS 020 00, to be placed at each end of the segment.
For wiring system:
b Quantum platform: please refer to our catalog.
b Lexium drive for brushless motors: please refer to our catalog “Lexium movement
command”.
b Altivar drive for asynchronous motors: please refer to our catalog “Progressive
starters and speed controllers”.
Wiring system
8 9
1
1 5 3 5 65
7 77
12
10
4
21
1
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com