Installation manual
4/21
4
4.1
References
Modicon TSX Micro
automation platform 5
ConneXium industrial Ethernet
References
Industrial ConneXium
Description Type of Ethernet network Available ports Reference Weight
kg
Hubs 10 Mbit/s 8 10BASE-T/100BASE-TX ports 499 NES 181 00 1,450
4 10BASE-T ports 499 NEH 104 10 0,520
3 10BASE-T ports
2 10BASEFL ports
499 NOH 105 10 0,900
100 Mbit/s 4 100BASE-TX ports 499 NEH 141 00 0,520
Switches 10/100 Mbit/s 5 10BASE-T/100BASE-TX ports 499 NES 251 00 0,190
5 10BASE-T/100BASE-TX ports
and 2 100BASE-TX ports
499 NES 171 00 1,450
5 100BASE-TX ports and
2 100BASE-FX ports
499 NOS 171 00 1,450
Tranceivers 10 Mbit/s 1 10BASE-T port and
1 10BASE-FL port
499 NTR 100 10
0,520
100 Mbit/s 1 100BASE-TX port and
1 100BASE-FX port
499 NTR 101 00 0,520
Description Type of connection Available ports Reference Weight
kg
Bridges Modbus Plus/Ethernet
(dual/simple pair Modbus)
1 10BASE-T (type RJ45) port or
10BASE2 (type BNC) or
10BASE5 (type AUI)
174 CEV 200 30 4,260
Modbus/Ethernet 1 10BASE-T/10BASE-TX port
(type RJ45)
174 CEV 300 20 0,500
Accessoires de raccordement
Description Utilisation Ports Ethernet disponibles Reference Weight
kg
Mini transceiver For connecting a10BASE-5
interface device (2) to a
10BASE-T Ethernet network
segment (twisted pair)
1 10BASE-5 (type AUI) port and
1 10BASE-T (type RJ 45) port
TSX ETH NTR1
–
Câbles de raccordement
Description Preformed at each end Length Reference Weight
kg
Shielded and foil twisted
pair cord cable
2 connectors RJ45 type
For connection to DTE terminal
2 m 490 NTW 000 02
(1)
–
5 m 490 NTW 000 05
(1)
–
12 m 490 NTW 000 12
(1)
–
40 m 490 NTW 000 40
(1)
–
80 m 490 NTW 000 80
(1)
–
Shielded and foil twisted
pair crossed cord cable
2 connectors RJ45 type
For connection between hubs,
switches and transceivers
5 m 490 NTC 000 05
(1)
–
15 m 490 NTC 000 15
(1)
–
40 m 490 NTC 000 40
(1)
–
80 m 490 NTC 000 80
(1)
–
Fiber optic cable for
terminal equipment to
optical cross connecting
bay
1 connector SC type and
1 connector MT/RJ
5 m 490 NOC 000 05 –
1 connector ST type (BFOC) and
1 connector MT/RJ
5 m 490 NOT 000 05 –
2 connectors MT/RJ type 5 m 490 NOR 000 05 –
(1) Category 5 of the EIA/TIA-568 international wiring-standard, class D of IEC 11801/EN50173
approved cables. Add the letter U to the end of the reference for CSA 22.1, NFPA 70 and UL
approved cables.
(2) For example, a TSX Series 7 PLC equipped with a TSX ETH 107 Ethernet module.
499 NEH 104 10
499 NES 251 00
499 NES 171 00
499 NTR 100 10
174 CEV 300 10
490 NTW 000
pp
490 NOC 000 0
p
C
haracteristics:
p
ages 4/17 to 4/20
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com
efesotomasyon - telemecanique inverter