UNCRATING AND SETUP
Remove your AC1005/AC2221 series changer from the
shipping box. Open the door. (The T-handle(s) are the
screw-in type and therefore, must be turned at least 10 times
counter-clockwise until it opens.) Inspect for any connectors
or components that may have been dislodged during shipping.
The matching locks and keys for your changer will be inside
the manila envelope along with this manual. To install the
locks, insert the cylinders into the round hole in the middle of
the T-handles push and turn until they stop. Now turn the key
and lock until you hear it “snap." Turn the key counter-
clockwise ¼ turn and remove the keys.
TEST:
Before permanently installing the changer, do a functional
test to verify that there is no shipping damage to your new
changer(s).
Plug the power cord into a grounded 120vac outlet. The
MLB programming is preset for a default 4 coin per
dollar pay-out of the hopper, and the Bill validator is
ready to accept $1-$5-$10-$20 dollar bills.
Fill the hopper with at least 100 coins. On the Power Supply
board turn the switch on the bottom right corner “ON”. The
rocker switch has an “I” and “O” printed on it. When the
“I” is pressed down the changer is “ON”.
MOUNTING THE AC1005/AC2221 INTO A WALL
IF YOU ARE UNSURE IN ANY WAY IN PROCEEDING
WITH THE FOLLOWING STEPS, PLEASE HIRE A
LOCAL PROFESSIONAL ELECTRICAN TO MOUNT
YOUR CHANGER FOR YOU!
1. Disconnect any and all AC power going to the changer.
(Unplug AC Line cord from the Power Module Board
and from the wall)
2. Slide the hopper out of the cabinet.
3. Note: You will need to verify with the building code that
it is allowable to plug the changer into a 3 prong
grounded outlet. If it is not, there must be 120VAC run
through conduit or other means to meet local codes to
the changer. If it is not required, proceed to step #6.
4. Let the electrician run the conduit, install the new
breaker, wire and help decide how the wiring will enter
the changer (from the side or the bottom). This will
affect the mounting location.
Note: Feeding the AC line cord from the bottom of the
changer is required for the AC2221, or when banking
two or more changers together. Simply remove the nuts
that secure the ‘L’ bracket, then rotate it and re-secure
with the same nuts.
5. After the conduit has been installed, proceed with the
mounting.
6. Find an appropriate wall to bolt the changer into. The
wall should have studs (use a stud finder) or be
constructed of concrete. Consult a professional with any
questions you may have.
7. NOTE: SECURING THE CHANGER WITH LESS
THAN 4 BOLTS OR WELDED ANGLE IRON MAY
BE DANGEROUS. EACH HOLE NEEDS A BOLT
THROUGH IT MOUNTED SECURELY INTO THE
WALL. MOUNTING THE CHANGER IN ANY
OTHER WAY MAY RESULT IN THE CHANGER
BEING TORN OUT OR FALLING OUT OF THE
WALL, RESULTING IN PERSONAL OR
CUSTOMER INJURY ALONG WITH ELECTRICAL
SHOCK.
8. Choose a height to mount the changer keeping in mind
that a handicapped person in a wheelchair should still be
able to insert a bill into the bill validator. (We
recommend no higher than 4 feet above the ground.)
9. Have someone hold the changer into the wall while
someone else marks the holes from the inside of the
machine. CAUTION:
THE AC1005 WEIGHS 71
POUNDS AND THE AC2221 WEIGHS 137 POUNDS;
DO NOT EXERT YOURSELF SO THAT YOU MAY
CAUSE AN INJURY.
10. BEFORE DRILLING THE FOUR MARKED HOLES
ENSURE THAT THERE ARE NO ELECTRICAL
WIRES, TELEPHONE LINES, GAS, OR WATER
LINES BEHIND THE WALL WHICH DISRUPTING
MAY CAUSE A LOSS OF LIFE OR PERSONAL
INJURY!
11. After drilling the holes, put the changer back into the
wall. Thread and tighten bolts.
12. Verify that the machine is securely mounted.
13. If the changer is required to be permanently connected
through a conduit, proceed to step #16.
14. Plug the power cord back into the Power Module Board
and into an AC wall outlet. Do not use an extension
cord unless allowed by the building electrical code.
15. Installation is finished and you can proceed to the
“Programming the Changer” section.
16. In order to continue you will need to purchase numerous
electrical components. We highly recommend hiring a
qualified electrician to perform the following!
A. Install the conduit box on the conduit entering the
cabinet in the lower left side of the cabinet.
B. Secure the 3 wires (hot, neutral, and ground) to the
AC wall outlet and the ground wire should also be
directly attached to the cabinet ground terminal.
C. Connect the AC line cord into the bottom of the
Power Module Board.
D. Plug the male end into the AC outlet just installed.
E. Properly fold the line cord to avoid sharp corners and
any other damage.
17. Proceed to the “Programming the Changer” section.
NOTE: The only way to get a duplicate
s
et of keys made is to save the red tag
that comes between the keys.
This ID # starts with “ACC ####”.