Instruction Sheet

Page 8
Blinks On once
approx every
40-45 seconds
Condition: DC Power is present.
Recommendation: None, alarm is operating properly.
OPERATIONAL SUMMARY
Silent
Blinks On
approx every
2 seconds
Condition: Nuisance Alarm.
Recommendation: If there is no hazard present, verify the alarm is mounted in the
correct location (see User's Manual, "AVOID THESE LOCATIONS" section). Reset alarm
as instructed below.
3 Beeps,
2 second pause,
Repeat
Blinks On
approx every
2 seconds
Condition: Originating Smoke Alarm.
Recommendation: If hazard is identified, please take all precautions if an alarm sounds
by calling an Emergency Service and getting out of the home.
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
Condition: One alarm has sensed smoke.
Recommendation: QUICK FIND
®
Alarm Origination - The QUICK FIND
®
feature will
allow you to immediately locate the originating alarm (once the alarms have stopped
sounding). To initiate QUICK FIND
®
, press the Test/Silence button on any alarm. After
releasing the button, the originating alarm will continue to sound for approx 60 seconds.
In a non-interconnected installation, it is necessary to test each alarm to determine the
originating alarm.
Blinks On once
approx every
40-45 seconds
Condition: Alarm needs to be reset due to varying conditions/previous alarms.
Recommendation: To Reset the Alarm, hold the Test/Silence button for approx 10 seconds
or temporarily remove (and then replace) the battery. This will clear alarm origination.
Reset alarm after every alarm event.
Silent
1 Chirp
approx every
40 seconds
Condition: Low Battery
Recommendation: Check to make sure the battery activation pull tab has been completely
removed, battery polarity is correct and the battery terminals are making contact with the
smoke alarm contacts in the battery drawer. If chirp continues, replace the 9V battery
(see User's Manual for recommended battery types).
3 Beeps,
2 second pause,
Repeat
Silent
(alarmed
previously)
CONDITION / RECOMMENDATION
HORN RED LED
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
AUDIBLE & VISUAL SIGNALS
Blinks On 3 times
approx every
35 seconds
1 Beep
approx every
35 seconds
Condition: Product End-of-Service Life alarm.
Recommendation: Replace alarm immediately. The product end-of-service life alarm
can be temporarily silenced for a 24 hour period for up to 25 days. After 25 days, the
warning cannot be silenced. The alarm should be replaced immediately.
Blinks On
approx every
2 seconds
Condition: Alarm has sensed smoke.
Recommendation: Silence Feature is activated by pressing and releasing the Test/Silence
button on the initiating/originating alarm while in alarm condition. Silence mode will last
for approx. 10 minutes with the red LED blinking once approx. every 10 seconds.
3 Beeps,
2 second pause,
Repeat
Blinks On once
approx every
40-45 seconds
3 Beeps approx
every 40 seconds
after LED flashes
Condition: Trouble/Service Alarm.
Recommendation: Replace Alarm.