Use and Care Manual

If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one
that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it only as
directed. Use of non-UL Listed products or improper use of UL Listed products may affect
the smoke alarm's sensitivity.
NUISANCE ALARM SILENCE FEATURE: This feature is to be used only when a known alarm
condition, such as smoke from cooking, activates the smoke alarm. The smoke alarm Silence
Feature is activated by pushing and releasing the Test/Silence button on the smoke alarm cover
while in alarm condition. The smoke alarm will automatically reduce sensitivity and the red LED will
blink on approx. every 10 seconds to indicate the alarm is in the Silence mode. The smoke alarm
will gradually regain normal sensitivity and sound the alarm if particles of combustion are still present.
The approx. 10 minute Silence feature may be used repeatedly until the air has cleared, by pushing
and releasing the Test/Silence button again. Resetting the smoke alarm after a nuisance alarm is
recommended.
NOTE: If the Test/Silence button is pressed and held during the Silence mode, the smoke alarm
will be tested normally. Upon the release of the Test/Silence button, the Silence mode will be restarted.
Before using the alarm Silence Feature, identify the source of smoke and be certain that safe
conditions exist.
(UTHA) MAINTENANCE: The smoke alarm is virtually maintenance free. However, under dusty
conditions, a vacuum hose may be used to clear the sensing chamber of dust.
REGULAR MAINTENANCE: Test the alarm at least once per week to verify it is operating properly.
Clean this alarm at least once a month to remove dust, dirt, insects and debris. Using a soft brush
or wand attachment to a vacuum cleaner, vacuum all sides and cover of smoke alarm. Be sure all
the vents are free of debris.
DO NOT use spray cleaning chemicals or insect sprays directly on or near the alarm. DO NOT
paint the alarm. Doing so may permanently damage the alarm and interfere with alarm’s ability to
sense smoke. The outside can be wiped with a damp cloth. DO NOT use any household cleaning
agents, solvents or sprays including compressed gas dusters or any other chemical on or near
your alarm. DO NOT disassemble or attempt to clean inside the alarm. This alarm contains no
serviceable parts.
If the alarm becomes contaminated by excessive dirt or grease, and cannot be cleaned, it should
be replaced immediately. Alarms have a limited life and should always be replaced 10 years from
the date of purchase.
AFTER CLEANING, REINSTALL YOUR ALARM AND
TEST YOUR ALARM BY USING THE TEST BUTTON
NEVER use an open flame of any kind to test this smoke alarm. You might accidentally damage
or set fire to the smoke alarm or to your home. The built-in test switch accurately tests the
smoke alarm's operation as required by Underwriters Laboratories Inc. (UL).
IMPORTANT CONSIDERATIONS
YOUR ALARM HAS BEEN DESIGNED WITH A PRODUCT END-OF-SERVICE LIFE WARNING
WHICH WILL SOUND AFTER APPROXIMATELY 10 YEARS OF OPERATION FROM INITIAL
POWER UP.
NOTE: MANUF ACTURER RECOMMENDS REPLACEMENT OF THIS ALARM 10 YEARS
AFTER DATE OF INSTALLATION. NOTE: NUMEROUS ALARMS OR PROLONGED
ALARMING IS NOT TYPICAL AND WILL CONSUME THE BATTERY CAPACITY, SHORTENING
THE LIFE OF THIS PRODUCT.
Page 6
BATTERY AND ALARM DEACTIVATION
This alarm uses a sealed battery. The battery should last for approximately 10 years under normal
operating conditions. The smoke alarm has a low battery indicator which is 2 chirps approx. every
60 seconds. The red LED blinks on once approx. every 2 minutes.
Due to the loud 85 decibel alarm, stand at arm's length away from the alarm or use ear protection
when testing. Weekly testing is required to ensure proper operation. Irregular or low volume
sound may indicate a defective alarm and it should be returned for service. Follow instructions
to prepare alarm for shipment or disposal.