Installation Guide
Page 9
CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL)
"Earlywarningredetectionisbestachievedbytheinstallationofredetectionequipmentinallroomsandareas
ofthehouseholdasfollows.Asmokealarminstalledineachseparatesleepingarea(inthevicinityof,butoutside
ofthebedrooms),andheatorsmokedetectorsinthelivingrooms,diningrooms,bedrooms,kitchens,hallways,
attics,furnacerooms,closets,utilityandstoragerooms,basementsandattachedgarages.
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,
UL217 BY UNDERWRITERS LABORATORIES, INC.
Blinks On once
approxevery
40-45 seconds
Stays On
Condition: AC Power is present. DC Power is present.
Recommendation: None, alarm is operating properly.
Blinks On once
approxevery
40-45 seconds
Off
Condition: AC Power is not present and alarm is receiving DC Power.
Recommendation: Check the breaker or fuse box for power.If
the breaker or fuse box looks normal, call a licensed electrician
for assistance.
OPERATIONAL SUMMARY
Silent
Silent
Blinks On
approxevery
2 seconds
Stays On Condition: Nuisance Alarm.
Recommendation: If there is no hazard present, verify the alarm is
mounted in the correct location (see User's Manual, "AVOID THESE
LOCATIONS"section).Resetalarmasinstructedbelow.
Horn does not
sound when other
alarms are active
or horn does not
sound when
interconnected
alarms test
Blinks On once
approxevery
40-45 seconds
Stays On
or Off
Condition: One or more alarms not responding to interconnected alarm.
Recommendation: Press and hold the smoke alarm Test/Silence
buttonforatleast5seconds.Ifstillnoalarm,turnoffACPoweratthe
circuitbreakerorfuseboxanddisconnectthealarmfromthemounting
bracketandmakesuretheconnectorplugissecurelyattachedon
units that did not alarm. If still no alarm, have a licensed electrician
make sure the yellow wire is not mistakenly or accidentally connected
to the white (neutral) wire.
3 Beeps,
2 second pause,
Repeat
Blinks On
approxevery
2 seconds
Stays On
Condition: Originating Smoke Alarm.
Recommendation:Ifhazardisidentied,pleasetakeallprecautions
if an alarm sounds by calling an Emergency Service and getting
out of the home.
3 Beeps,
2 second pause,
Repeat
Off Stays On
Condition: Non-originating Smoke Alarm. Another interconnected
smoke alarm has sensed smoke, causing all interconnected units
to alarm.
Recommendation:Ifhazardisidentied,pleasetakeallprecautions
if an alarm sounds by calling an Emergency Service and getting
out of the home.
Blinks On once
approxevery
40-45 seconds
(normal operation
mode) or Blinks On
onceapproxevery
10 seconds
(silence mode)
Stays On Condition: One alarm has sensed smoke.
Recommendation: QUICK FIND
®
Alarm Origination - In an
interconnectedsystem,itisdifculttodeterminewhichalarminitiated
the alarms to sound. The QUICK FIND
®
feature will immediately
allow you to locate the originating alarm (once the alarms have
stopped sounding). To initiate QUICK FIND
®
, press the Test/Silence
buttononanyalarm.Afterreleasingthebutton,thetestsequence
will sound and then stop. Then, the originating alarm will continue to
soundforapprox50seconds.Inanon-interconnectedinstallation,
it is necessary to test each alarm to determine the originating alarm.
Reset the originating alarm.
Blinks On once
approxevery
40-45 seconds
Stays On Condition:Alarm needs to be reset due to varying conditions/
previous alarms.
Recommendation:ToResettheAlarm,holdtheTest/Silencebutton
forapprox10seconds.Thiswillclearalarmorigination.Resetafter
each smoke alarm event.
Silent
1 Chirp
approxevery
40 seconds
Stays On Condition: Low Battery
Recommendation: Checktomakesurethebatteryactivationpull
tabhasbeencompletelyremoved,batterypolarityiscorrectandthe
batteryterminalsaremakingcontactwiththesmokealarmcontacts
inthebatterydrawer.Ifchirpcontinues,replacethe9Vbattery(see
User'sManualforrecommendedbatterytypes).
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
Stays On Condition: Alarm has sensed smoke.
Recommendation: Silence Feature is activated by pressing and
releasingtheTest/Silencebuttonontheinitiatingalarmwhileinalarm
condition.Silencemodewilllastforapprox8-12minuteswiththered
LEDblinkingonceapprox.every10seconds.
Blinks On
approxevery
2 seconds
Silent
(alarmed
previously)
CONDITION / RECOMMENDATION
HORN RED LED GREEN LED
Blinks On once
approxevery
40-45 seconds
(normal operation
mode) or Blinks On
onceapproxevery
10 seconds
(silence mode)
Blinks On once
approxevery
40-45 seconds
1 Beep
approxevery
60 seconds
Condition: Product End-of-Service Life Signal.
Recommendation: Replace alarm immediately. To silence signal
forapprox.9 hours,press andreleasetheTestbutton.The alarm
will sound for approximately 60 seconds while it resets.After the
resetfunctioniscompleted,theproductend-of-servicesignalwillbe
silentforapprox.9hoursandwillreactivateafterthesilenceperiod.
Stays On