Use and Care Manual
NEVER use an open flame of any kind to test this smoke alarm. You might accidentally damage
or set fire to the smoke alarm or to your home. The built-in test switch accurately tests the
smoke alarm's operation as required by Underwriters Laboratories Inc. (UL).
(UTHA) Sensitivity Indicating Means
The sensitivity indicating means for this Smoke and Fire Alarm is the use of the analyzer for Smoke
Detectors Model 501-A or 501-A/Bat Aerosol Generator Manufactured by Gemini Scientific Corp.,
1122-B Aster Ave., Sunnyvale, CA 94086.
The
Equivalent UL 268 Light obscuration %/Ft as measured by this instrument must be within the
obscuration listed on the back of this alarm.
(UTHA) Go/No-Go Field Test
The Go/No-Go test for this smoke and fire alarm is to use one of the following UL listed can-type aerosol
smoke alarm testers. The instructions for use are printed on the canister. Home Safeguard, Model 25S.
If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one
that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it only as
directed. Use of non-UL Listed products or improper use of UL Listed products may affect
the smoke alarm's sensitivity.
(UTHA) MAINTENANCE:
The alarm is virtually maintenance free. However, under dusty conditions, a vacuum hose may be
used to clear the sensing chamber of dust.
Clean the alarm at least once a month to remove dust, dirt, insects or debris. Always turn off
power to alarm before cleaning. Using a soft brush or wand attachment to a vacuum cleaner, vacuum
all sides and cover of the alarm. Be sure all the vents are free of debris.
If the alarm is false alarming and cannot be restored to normal operation, the alarm should be
replaced.
WEEKLY TESTING
• NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire
to the alarm or to your home. The built-in test switch accurately tests the unit's operation as
required by the UL 217, UL 2034 and UL 1484 Standards. NEVER use vehicle exhaust! Exhaust
may cause permanent damage and voids your warranty.
• DO NOT stand close to the alarm when the horn is sounding. Exposure at close range may be
harmful to your hearing. When testing, step away when the horn starts sounding.
It is important to test this alarm every week to make sure it is working properly.
USING THE TEST FEATURE:
Press and release the TEST button on the alarm cover.
During testing, you will hear: 3 beeps (red LED on), 2 second pause, 3 beeps (red LED on), 6
second pause, 4 beeps (red LED on), 2 second pause, 1 beep (blue LED on).
If the alarm does not sound properly:
1. Make sure the AC power is applied and the battery is fresh and installed correctly.
2. Test the alarm again.
WHEN THE SMOKE ALARM SIGNAL IS SILENCED: The alarm will remain silent for up to approx.
8-12 minutes (with the red LED blinking on approx. every 10 seconds) and then return to normal
operation. Ventilate area. If the smoke has not cleared within the silence period, the unit will go
back into alarm.
IMPORTANT!
The Silence feature is intended to temporarily silence the alarm horn. It will not correct a Smoke,
CO or Natural Gas problem. The Gas Alarm signal cannot be silenced.
RESET: To reset the QUICK FIND
®
Alarm Origination condition, press and hold the TEST/
SILENCE button on any alarm for at least 10 seconds, or until the blue LED turns on, and
then release. Reset after each alarm. The reset feature will reset all interconnected units.
SENSOR TROUBLE/SERVICE ALARM: If the alarm chirps 3 times approx. every 20 seconds
and cannot be restored to normal operation, the alarm should be replaced immediately.