Installation Guide

Page 8
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,
UL217 BY UNDERWRITERS LABORATORIES, INC.
Blinks On once
approx every
40-45 seconds
Condition: DC Power is present.
Recommendation: None, alarm is operating properly.
OPERATIONAL SUMMARY
Silent
Blinks On
approx every
2 seconds
Condition: Nuisance Alarm.
Recommendation: If there is no hazard present, verify the alarm is mounted in the
correct location (see User's Manual, "AVOID THESE LOCATIONS" section). Reset
alarm as instructed below.
3 Beeps,
2 second pause,
Repeat
Blinks On
approx every
2 seconds
Condition: Originating Smoke Alarm.
Recommendation: If hazard is identied, please take all precautions if an alarm sounds
by calling an Emergency Service and getting out of the home.
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
Condition: One alarm has sensed smoke.
Recommendation: QUICK FIND
®
Alarm Origination - The QUICK FIND
®
feature will allow
you to immediately locate the originating alarm (once the alarms have stopped sounding).
To initiate QUICK FIND
®
, press the Test/Silence button on any alarm. After releasing the
button, the originating alarm will continue to sound for approx 60 seconds. It is necessary to
test each alarm to determine the originating alarm in a 9 volt non-interconnected installation.
Blinks On once
approx every
40-45 seconds
Condition: Alarm needs to be reset due to varying conditions/previous alarms.
Recommendation: To Reset the Alarm, hold the Test/Silence button for approx 10 seconds
and release or temporarily remove (and then replace) the battery. This will clear alarm
origination. Reset alarm after every alarm activation.
Silent
1 Chirp
approx every
40 seconds
Condition: Low Battery
Recommendation: Check to make sure the battery activation pull tab has been completely
removed, battery polarity is correct and the battery terminals are making contact with the
smoke alarm contacts in the battery drawer. If chirp continues, replace the 9V battery
(see User's Manual for recommended battery types).
3 Beeps,
2 second pause,
Repeat
Silent
(alarmed
previously)
CONDITION / RECOMMENDATION
HORN RED LED
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
AUDIBLE & VISUAL SIGNALS
Blinks On once
approx every
40-45 seconds
1 Beep
approx every
60 seconds
Condition: End-of-Service Life alarm.
Recommendation: Replace alarm immediately. It will not detect smoke in this condition.
Blinks On
approx every
2 seconds
Condition: Alarm has sensed smoke.
Recommendation: Silence Feature is activated by pressing and releasing the Test/
Silence button on the initiating/originating alarm while in alarm condition. Silence mode
will last for approx. 8-12 minutes with the red LED blinking once approx. every 10 seconds.
3 Beeps,
2 second pause,
Repeat