Use and Care Manual
Page 13
GAS
BLUE LED
AUDIBLE & VISUAL SIGNALS
POWER
GREEN LEDHORN
OPERATIONAL SUMMARY (continued)
CONDITION / RECOMMENDATION
CO
RED LED
Silent
(alarmed
previously)
Off and Blinks
On approx
every 5
seconds
until reset
On and Blinks
Off approx
every 20
seconds
Off and Blinks
On approx
every 5
seconds
until reset
Condition: Alarm needs to be reset due to abnormal operation/previous
alarms.
Recommendation: To reset the alarm, hold the Test/Silence button for 10
seconds or until the blue LED turns on. This will clear the alarm origination and
latching LEDs. Reset after each alarm event.
Horn has
stopped
sounding
OffOn and Blinks
Off approx
every 20
seconds
Condition: Latching CO LED indicator. The alarm has previously detected
CO and had alarmed.
Recommendation: Follow the reset instructions to remove the latching LED.
Horn has
stopped
sounding
On and Blinks
Off approx
every 20
seconds
Off Condition: Latching GAS LED indicator. The alarm has previously detected
GAS and had alarmed.
Recommendation: Follow the reset instructions to remove the latching LED.
1 Chirp
approx.
every 40
seconds
OffOn and Blinks
Off approx
every 20
seconds
Off
Condition: Low battery.
Recommendation: Check to make sure a battery is present in the drawer,
the battery activation pull tab has been completely removed, battery polarity
is correct and the battery terminals are making contact with the smoke alarm
contacts in the battery drawer. If chirp continues, replace the 9V battery (see
User’s Manual for recommended battery types).
3 Chirps
approx.
every 20
seconds
OffOn and Blinks
Off approx
every 20
seconds
Off Condition: Sensor Trouble/Sensor End-of-Life Alarm.
Recommendation: Reset the alarm. If this does not clear the problem,
replace alarm.
2 Chirps
approx.
every 20
seconds
OffOn and Blinks
Off approx
every 20
seconds
Off Condition: Product End-of-Service Life Notification.
Recommendation: Replace the alarm immediately. The product end-of-
service life notification can be temporarily silenced for a 10 hour period for up to
20 days. After 20 days, the warning cannot be silenced. The alarm should be
replaced immediately.
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 2034 and UL 1484
* During 120 volt operation On and Blinks Off approx. every 20 seconds.
During 9 volt (DC backup) operation, blinks On approx. every 40 seconds.
Off and Blinks
On approx
every 5
seconds
until reset
Off and Blinks
On approx
every 5
seconds
until reset