Installation Guide
Page 13
GAS
BLUE LED
AUDIBLE & VISUAL SIGNALS
POWER
GREEN LED
HORN
OPERATIONAL SUMMARY (continued)
CONDITION / RECOMMENDATION
CO
RED LED
Silent
(alarmed
previously)
Off and Blinks
On approx
every 5
seconds
until reset
On and Blinks
Off approx
every 20
seconds
Off and Blinks
On approx
every 5
seconds
until reset
Condition: Alarm needs to be reset due to abnormal operation/previous
alarms.
Recommendation: To reset the alarm, hold the Test/Silence button for 10
seconds or until the blue LED turns on. This will clear the alarm origination
and latching LEDs. Reset after each alarm event.
Horn has
stopped
sounding
OffOn and Blinks
Off approx
every 20
seconds
Condition: Latching CO LED indicator. The alarm has previously detected
CO and had alarmed.
Recommendation: Follow the reset instructions to remove the latching
LED.
Horn has
stopped
sounding
On and Blinks
Off approx
every 20
seconds
Off Condition: Latching GAS LED indicator. The alarm has previously detected
GAS and had alarmed.
Recommendation: Follow the reset instructions to remove the latching
LED.
1 Chirp
approx.
every 40
seconds
OffOn and Blinks
Off approx
every 20
seconds
Off
Condition: Low battery.
Recommendation: Check to make sure a battery is present in the drawer,
the battery activation pull tab has been completely removed, battery polarity
is correct and the battery terminals are making contact with the smoke alarm
contacts in the battery drawer. If chirp continues, replace the 9V battery (see
User’s Manual for recommended battery types).
3 Chirps
approx.
every 20
seconds
OffOn and Blinks
Off approx
every 20
seconds
Off Condition: Sensor Trouble/Sensor End-of-Life Alarm.
Recommendation: Reset the alarm. If this does not clear the problem,
replace alarm.
2 Chirps
approx.
every 20
seconds
OffOn and Blinks
Off approx
every 20
seconds
Off Condition: Product End-of-Service Life Notication.
Recommendation: Replace the alarm immediately. The product end-of-
service life notication can be temporarily silenced for a 10 hour period for
up to 20 days. After 20 days, the warning cannot be silenced. The alarm
should be replaced immediately.
* During 120 volt operation On and Blinks Off approx. every 20 seconds.
During 9 volt (DC backup) operation, blinks On approx. every 40 seconds.
Off and Blinks
On approx
every 5
seconds
until reset
Off and Blinks
On approx
every 5
seconds
until reset
RESET INSTRUCTIONS: Press the Test/Silence button for 10 seconds, or until the blue LED turns on, and then release. This will clear the alarm
latching LED’s and clear the alarm origination. Be sure to RESET alarms after each alarm event.
QUICK FIND
®
Alarm Origination/Location Feature: The QUICK FIND
®
feature will allow you to immediately locate the originating alarm (the alarm
that triggered the other alarms), once the alarms have stopped sounding.
1. Press and hold the test/silence button on any alarm until the test sequence on this alarm begins. Release the test button. The specic horn pattern/
sequence is designated by the alarm type.
2. Once this test sequence ends, the originating alarm continues to sound for approximately 60 seconds, which provides ample time to locate the
originating alarm.
3. Remember to reset the originating alarm in order to clear the QUICK FIND
®
and return the system to normal operation.
NOTE: If you have any additional questions about the operation of your alarm, please contact our Customer Service Department at 1-800-390-4321,
and we will gladly assist you.