Blinks On once
approx every
40-45 seconds
Condition: DC Power is present.
Recommendation: None, alarm is operating properly.
OPERATIONAL SUMMARY
Silent
Blinks On once
approx every
second
Condition: Nuisance Alarm.
Recommendation: If there is no hazard present, verify the alarm is mounted in the
correct location (see User's Manual, "AVOID THESE LOCATIONS" section). Reset
alarm as instructed below.
3 Beeps,
2 second pause,
Repeat
Blinks On once
approx every
second
Condition: Originating Smoke Alarm.
Recommendation: If hazard is identified, please take all precautions if an alarm
sounds by calling an Emergency Service and getting out of the home.
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks on once
approx every
10 seconds
(silence mode)
Condition: One alarm has sensed smoke and is now silent.
Recommendation: QUICK FIND
®
Alarm Origination - The QUICK FIND
®
feature
will allow you to immediately locate the originating alarm (once the alarm has stopped
sounding). To initiate QUICK FIND
®
, press the Test/Silence button on any alarm.
After releasing the button, the originating alarm will continue to sound for approx 60
seconds. In a non-interconnected installation, it is necessary to test each alarm to
determine the originating alarm. Reset the originating alarm.
Condition: Alarm needs to be reset due to varying conditions/previous alarms.
Recommendation: To Reset the Alarm, hold the Test/Silence button for approx 10
seconds, or temporarily remove (and then replace) the battery. This will clear alarm
origination.
Silent
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
Condition: Alarm has sensed smoke.
Recommendation: Silence Feature is activated by pressing and releasing the Test/
Silence button on the initiating alarm while in alarm condition. Silence mode will last
for approx 8-12 minutes with the red LED blinking once approx. every 10 seconds.
Blinks On once
approx every
second
Silent
(alarmed
previously)
CONDITION / RECOMMENDATION
HORN
RED LED
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks on once
approx every
10 seconds
(silence mode)
ALARM AUDIBLE & VISUAL SIGNALS
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,
UL217 BY UNDERWRITERS LABORATORIES, INC.
Blinks On once
approx every
40-45 seconds
1 Chirp
approx every
40 seconds
Condition: Low Battery
Recommendation: Check to make sure the battery activation pull tab has been
completely removed, battery polarity is correct and the battery terminals are making
contact with the smoke alarm contacts in the battery drawer. If chirp continues,
replace the 9V battery (see User's Manual for recommended battery types).