Use and Care Guide
Page 17
GAS
BLUE LED
AUDIBLE & VISUAL SIGNALS
HORN
OPERATIONAL SUMMARY (continued)
CONDITION / RECOMMENDATION
Horn has
stopped
sounding
Off
Off
Condition: Latching smoke LED indicator. The alarm has
previously detected smoke and had alarmed.
Recommendation: Follow the reset instructions to remove
the latching LED.
CO
RED LED
Silent
(alarmed
previously)
Off or Blinks
On approx
every 5
seconds
until reset
Off or Blinks
On approx
every 5
seconds
until reset
Condition: Alarm needs to be reset due to abnormal
operation/previous alarms.
Recommendation: To reset the alarm, hold the Test/Silence
button for 10 seconds or until the blue LED turns on. This
will clear the alarm origination and latching LEDs. Reset
after each alarm event.
Horn has
stopped
sounding
Off
Off
Condition: Latching CO LED indicator. The alarm has
previously detected CO and had alarmed.
Recommendation: Follow the reset instructions to remove
the latching LED.
Horn has
stopped
sounding
Off
Off
Condition: Latching GAS LED indicator. The alarm has
previously detected GAS and had alarmed.
Recommendation: Follow the reset instructions to remove
the latching LED.
1 Chirp
approx.
every 40
seconds
Off Off Condition: Low battery.
Recommendation: Check to make sure a battery is present
in the drawer, the battery activation pull tab has been
completely removed, battery polarity is correct and the battery
terminals are making contact with the smoke alarm contacts
in the battery drawer. If chirp continues, replace the 9V battery
(see User’s Manual for recommended battery types).
3 Chirps
approx.
every 20
seconds
Off Off Condition: Sensor Trouble/Sensor End-of-Life Alarm.
Recommendation: Reset the alarm. If this does not clear
the problem, replace alarm.
2 Chirps
approx.
every 20
seconds
Off Off
Condition: Product End-of-Service Life Notication.
Recommendation: Replace the alarm immediately. The
product end-of-service life notication can be temporarily
silenced for a 10 hour period for up to 20 days. After 20
days, the warning cannot be silenced. The alarm should be
replaced immediately.
Silent
(alarmed
previously)
Off or Blinks
On approx.
every 5
seconds until
reset
Off or
Blinks On
approx.
every 5
seconds
until reset
* During 120 volt operation On and Blinks Off approx. every 20 seconds.
During 9 volt (DC backup) operation, blinks On approx. every 40 seconds.
POWER
GREEN LED
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
SMOKE
RED LED
Off and Blinks
On approx
every 5
seconds
until reset
Off and Blinks
On approx
every 5
seconds
until reset
Off or Blinks
On approx
every 5
seconds
until reset
Off
Off
Off
Off or Blinks
On approx
every 5
seconds
until reset
Off and Blinks
On approx
every 5
seconds
until reset
Condition: Previous alarm condition at unidentied source.
Recommendation: QUICK FIND
®
Alarm Origination - In an
interconnected system, it is difcult to determine which alarm
initiated the alarms to sound. The QUICK FIND
®
feature will
immediately allow you to locate the originating alarm (once the
alarms have stopped sounding). To initiate QUICK FIND
®
, press
the Test/Silence button on any alarm. After releasing the button,
the test sequence will sound and then stop. Then, the originating
alarm will continue to sound for approx 50 seconds. In a non-
interconnected installation, it is necessary to test each alarm
to determine the originating alarm. Reset the originating alarm.