Specifications

34
URC 2015 Total Control Product Catalog
Vivido™ Master and Accessory Switches
Switches are ideal for controlling wall outlets and devices that cannot be dimmed
(e.g., outdoor lights, radios) and standard wall outlets. Wall outlets should never be
controlled by a dimmer due to the risk that someone might plug in an inappropriate
device (anything with an electric motor such as a vacuum cleaner or fan) which can
cause damage or potenally create safety hazards.
In circuits where a light is controlled by more than one switch, one Vivido Master
Switch and the appropriate number of Accessory Switches (maximum ve) must be
installed. No traveler wire necessary.
Common Key Features
• Can be associated with up to 5 other devices
• Electro-mechanical push buon for ON/OFF operaon
• Patented indicator system alerts if switch is not set upon the network
• Blue LED illuminates to indicate ON/OFF status
• Single buon programming
• Programmable delayed OFF mode up to 4 minutes (default is 10 seconds)
• Child Lockout feature
• Panic mode for increased security & integraon with security systems
• All-ON/All-OFF inclusion
• Congurable “power up state”
• Compable with any Decora® wall plate (not included)
• Available in White, Black and Light Almond
Accessory Switch Key Features
• Adds wireless control eliminang the needs for tradional three-way wiring (up to ve locaons)
• Compable with Vivido Master Switches only
Specicaons
Performance: Rang: 120V/AC, 60Hz
Maximum Amperage: 15A (applies to Master Switch only)
Performance
Consideraon: A URC Z-Wave enabled device must be within 30 feet of another Z-Wave enabled device
to parcipate in a Z-Wave wireless mesh network. Any one dimmer or switch can be
associated with up to 5 devices (dimmers, switches, receptacles, or plug-in modules).
Terminaons: All-load switches have four 6” pre-stripped wire leads for line, load, ground and neutral;
no-neutral switches have three wires. Switches designated “all-load” require connecon
to a neutral wire. Controlling LED, CFL, ELV and Fluorescent Dimming Ballasts requires an
all-load switch.