Specifications

3-36 Ringing in Series II peripherals
297-1001-131 Standard 06.01 October 2000
At the LCE frame/cabinet
40
Put on a wrist strap.
41 Power down, remove, and make the DIP switch changes to RG-0.
42 Reseat RG-0 and restore power.
Refer to the
Hardware Description Manual
, 297-8991-805 for information on
DIP switch settings for the ringing generator.
At the MAP terminal
43 To return unit 0 of the first (currently posted) LCM to service, type
> RTS UNIT 0
and press the Enter key.
44 To return unit 0 of the second LCM to service, type
> POST LCM 0 1
and press the Enter key.
> RTS UNIT 0
and press the Enter key.
45 Use the SWRG command to align the RGs to the recommended RG
assignment for each LCM. Type
> SWRG UNIT PM
and press the Enter key.
Repeat this step for the other unit.
Note:
The recommended RG assignment for LCM 0 is RG-0. The
recommended RG assignment for LCM 1 is RG-1.
Refer to Figure 3-4, "LCE frame" on page 3-13 for an illustration of the LCM
units and the RGs.
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect it to the
wrist strap grounding point on the left side of the frame supervisory
panel of the LCM. This protects the equipment against damage caused
by static electricity.
WARNING
Equipment damage
Take the following precautions when removing or inserting a card:
1. Do not apply direct pressure to the components.
2. Do not force the cards into the slots.